SsangYong Korando II (1996-2006 year). Manual - part 421

 

  Index      SsangYong     SsangYong Korando II - service repair manual 1996-2006 year

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  419  420  421  422   ..

 

 

SsangYong Korando II (1996-2006 year). Manual - part 421

 

 

SSANGYONG  MY2002

9B-8  LIGHTING SYSTEM

Turn Signal Lamps and Hazard Lamps Do Not Work

Step

1

2

3

4

5

6

7

8

Action

Check fuses F26, F2 and EF10, EF20.
Is either fuse blown?
Check for a short circuit and repair if necessary
Replace the fuse.
Is the repair complete?
1. Turn the ignition on.
2. Check the voltage at fuse F26, F2 and EF10,

EF20.

Does the battery voltage available at both fuses F26,
F2 and EF10, EF20 equal the specified value?
1. Turn the hazard lamp switch on.
2. Remove each or the inoperative lamps from

socket.

3. Test each lamp socket positive terminal with a

voltmeter.

Does the battery voltage pulsing at the turn-signal,
hazard-lamp socket positive terminal equal the
specified value?
At each bulb socket, use an ohmmeter to check the
ground circuit.
Is the resistance equal to the specified value?
Replace any faulty turn signal/hazard bulbs.
Is the repair complete?
Repair the power supply circuit to fuses.
Is the repair complete?
Repair the open ground circuit.
Is the repair complete?

Yes

Go to Step 2

System OK

Go to Step 4

Go to Step 5

Go to Step 6

System OK

System OK

System OK

No

Go to Step 3

-

Go to Step 7

Go to Step 9

Go to Step 8

-

-

-

Value(s)

-

-

11 - 14 v

11 - 14 v

-

-

-

TAIL LAMPS

Taillamps Do Not Work

Step

1

2

3

4

5

Action

Check fuse EF12.
Is EF12 blown.
1. Check for a short circuit and repair it, if necessary.
2. Replace the fuse.
Is the repair complete?
1. Press the brake pedal down.
2. Check the positive terminals of the bulb sockets

with a test lamp.

Does the test lamp illuminate?
Connect an ohmmeter between ground and the
stoplamp ground terminal.
Is the resistance equal to specified value?
Repair the ground circuit.
Is the repair complete?

Yes

Go to Step 2

System OK

Go to Step 2

-

System OK

No

Go to Step 3

-

Go to Step 6

Go to Step 4

-

Value(s)

-

-

-

-

LIGHTING SYSTEM  9B-9

SSANGYONG  MY2002

Trun Signal Lamps and Hazard Lamps Do Not Work (Cont’d)

Step

9

10

11

12

13

14

15

16

17

18

19

Action

1. Turn on the hazard switch.
2. Test the blinker unit connector terminal 49 with a

voltmeter.

Does the battery voltage pulsing at the blinker unit
terminal 113 equal the specified value?
1. Turn on the hazard switch.
2. Test the blinker unit connector terminal 31 with a

voltmeter.

Does the battery voltage pulsing at the blinker unit
terminal 31 equal the specified value?
1. Disconnect the blinker unit from the connector.
2. Use an ohmmeter to check between ground and

the connector for terminal 31, 49 of the blinker
unit.

Is the resistance equal to the specified value?
Repair the blinker unit ground connection.
Is the repair complete?
Replace faulty blinker unit.
Is the repair complete?
1. Disconnect the hazard switch connector.
2. Check for voltage at terminal 49.
3. Turn the ignition on.
4. Check for voltage at terminal 111.
Does the battery voltage available at both terminals
equal the specified value?
1. Remove the hazard switch.
2. Turn the hazard switch OFF.
3. Check for continuity between terminals 66 and

111.

4. Turn the hazard switch on.
5. Check for continuity between terminals 66 and

64.

Do both tests show the specified value?
1. Remove the hazard switch.
2. Turn the hazard switch to the on position.
3. Use an ohmmeter to check for continuity between

terminals 112, 62, and 63.

Does the continuity between terminals 112, 62, and
63 equal the specified value?
Replace the faulty hazard switch.
Is the repair complete?
Repair the open circuit between hazard switch
terminal 113 and blinker unit terminal 42.
Is the repair complete?
Repair the open circuit between the hazard switch
and the fuses EF12 or F11.
Is the repair complete?

Yes

Go to Step 15

Go to Step 11

Go to Step 13

System OK

System OK

Go to Step 15

Go to Step 18

System OK

System OK

System OK

System OK

No

Go to Step 10

Go to Step 14

Go to Step 12

-

-

Go to Step 19

Go to Step 16

System OK

-

-

-

Value(s)

11 - 14 v

11 - 14 v

0 - 0.5 

-

-

11 - 14 v

-

-

-

SSANGYONG  MY2002

9B-10  LIGHTING SYSTEM

Hazard Lamps Do Not Operate, Turn Signals Are OK (Cont’d)

Step

1

2

3

4

5

6

7

8

9

10

Action

Check fuses F26 and F2.
Is fuse EF12 blown?
1. Check for a short circuit and repair if necessary.
2. Replace the fuse.
Is the repair complete?
Use a voltmeter to check for power to fuse F26.
Does the battery voltage available at fuse F26 equal
the value specified?
Repair the power supply circuit to fuse F2.
Is the repair complete?
1. Disconnect the hazard switch connector.
2. Use a voltmeter to check power to the hazard

switch terminal 112.

Does the battery voltage available at connector
terminal 112 equal the value specified?
1. Remove the hazard switch and disconnect it for

testing.

2. Turn the hazard switch to the on position.
3. Test with an ohmmeter between terminals 112

and 113.

Is the resistance equal to the specified value?
1. With the hazard switch still removed and discon-

nected for testing, turn the hazard switch to
the on position.

2. Use an ohmmeter to check between terminals 11,

62, and 63.

Is the resistance equal to the specified value?
Repair the open circuit between the hazard switch
connector and splice connector.
Is the repair complete?
Repair the open circuit between the hazard switch
connector terminal 111 and fuse F26.
Is the repair complete?
Replace the faulty hazard switch.
Is the repair complete?

Yes

Go to Step 2

System OK

Go to Step 5

System OK

Go to Step 6

Go to Step 7

Go to Step 8

System Ok

System OK

System OK

No

Go to Step 3

-

Go to Step 4

-

Go to Step 9

Go to Step 10

Go to Step 10

-

-

-

Value (s)

-

-

11 - 14 v

-

11 - 14v

-

-

-

LIGHTING SYSTEM  9B-11

SSANGYONG  MY2002

INTERIOR ROOM AND LUGGAGE LAMPS

Interior Room Lamp Inoperative

Step

1

2

3

4

5

6

7

8

9

10

Action

1. Remove the interior room lamp bulb and inspect

the filament.

2. If the filament is not broken, test the bulb using

the vehicle’s battery and a jumper wire.

Does the bulb pass the visual and physical checks?
1. Check for a short circuit and repair if necessary.
2. Replace the fuse.
Is the repair complete?
Use a voltmeter to check for power to fuse F1.
Does the battery voltage available at fuse F1 equal
the value specified?
Repair the power supply circuit to fuse F1.
Is the repair complete?
1. Disconnect the hazard switch connector.
2. Use a volmeter to check power to the hazard

switch terminal 3.

Does the battery voltage available at connector
terminal 3 equal the value specified?
1. Remove the hazard switch and disconnect it for

testing.

2. Turn the hazard switch to the on position.
3. Test with an ohmmeter between terminals 8 and

7.

Is the resistance equal to the specified value?
1. With the hazard switch still removed and

disconnected for testing, turn the hazard switch to
the on position.

2. Use an ohmmeter to check between terminals 111

and 63.

Is the resistance equal to the specified value?
Repair the open circuit between the hazard switch
connector and splice connector.
Is the repair complete?
Repair the open circuit between the hazard switch
connector terminal 3 and fuse F1.
Is the repair complete?
Replace the faulty hazard switch.
Is the repair complete?

Yes

Go to Step 3

System OK

Go to Step 5

System OK

Go to Step 6

Go to Step 7

Go to Step 8

System OK

System OK

System OK

No

Go to Step 2

-

Go to Step 4

-

Go to Step 9

Go to Step 10

Go to Step 10

-

-

-

Value (s)

-

-

11 - 14 v

-

-

-

-

-

 

 

 

 

 

 

 