BRC-82 < DTC/CIRCUIT DIAGNOSIS > [VDC/TCS/ABS] VDC OFF INDICATOR LAMP VDC OFF INDICATOR LAMP Description INFOID:0000000006165941 ×: ON –: OFF Component Function Check INFOID:0000000006165942 1. VDC OFF INDICATOR LAMP OPERATION CHECK 1 Check that the lamp illuminates for approximately 2 seconds after the ignition switch is turned ON. YES >> GO TO 2 NO >> Go to diagnosis procedure. Refer to 2. VDC OFF INDICATOR LAMP OPERATION CHECK 2 Check that the VDC OFF indicator lamp in the combination meter turns ON/OFF correctly when operating the VDC OFF switch. YES >> Inspection End NO >> Check VDC OFF switch. Refer to . Diagnosis Procedure INFOID:0000000006165943 1. CHECK VDC OFF SWITCH Check that the VDC OFF indicator lamp in the combination meter turns ON/OFF correctly when operating the VDC OFF switch. YES >> GO TO 2 NO >> Check VDC OFF switch. Refer to . 2. CHECK SELF-DIAGNOSIS Perform ABS actuator and electric unit (control unit) self-diagnosis. Refer to Is the inspection result normal? YES >> GO TO 3 NO >> Check items displayed by self-diagnosis. 3. CHECK COMBINATION METER Check if the indication and operation of combination meter are normal. Refer to . Is the inspection result normal? YES >> Replace ABS actuator and electric unit (control unit). Refer to BRC-116, "Removal and Installa- . NO >> Replace combination meter. Refer to MWI-93, "Removal and Installation" Condition VDC OFF indicator lamp Ignition switch OFF – For 2 seconds after turning ON ignition switch × 2 seconds later after turning ON ignition switch – VDC OFF switch turned ON. (VDC function is OFF.) × VDC/TCS function is malfunctioning. × ABS function is malfunctioning. × EBD function is malfunctioning. × |