содержание .. 181 182 183 184 ..
BRC-198 < DTC/CIRCUIT DIAGNOSIS > [WITH VDC (ESP)] VDC (ESP) OFF INDICATOR LAMP VDC (ESP) OFF INDICATOR LAMP Component Function Check INFOID:0000000010723740 1. CHECK VDC OFF INDICATOR LAMP FUNCTION (1) Check that VDC OFF indicator lamp in combination meter turns ON for approx. 1 second after ignition switch CAUTION: Never start engine. YES >> GO TO 2. NO >> Proceed to BRC-198, "Diagnosis Procedure" 2. CHECK VDC OFF INDICATOR LAMP FUNCTION (2) Check that VDC OFF indicator lamp in combination meter turns ON/OFF when VDC OFF switch is operated. YES >> INSPECTION END NO >> Check VDC OFF switch system. Refer to BRC-191, "Diagnosis Procedure" . Diagnosis Procedure INFOID:0000000010723741 1. CHECK ABS ACTUATOR AND ELECTRIC UNIT (CONTROL UNIT) POWER SUPPLY AND GROUND CIR- CUIT Perform the trouble diagnosis for ABS actuator and electric unit (control unit) power supply and ground circuit. BRC-188, "Diagnosis Procedure" Is the inspection result normal? YES >> GO TO 2. NO >> Repair or replace error-detected parts. 2. CHECK VDC OFF INDICATOR LAMP SIGNAL (1) With CONSULT 1. Turn the ignition switch ON. CAUTION: Never start engine. 2. Select “ABS”, “DATA MONITOR” and “OFF LAMP” according to this order. 3. Check that data monitor displays “On” for approx. 1 second after ignition switch is turned ON, and then Is the inspection result normal? YES >> GO TO 3. NO >> Replace the ABS actuator and electric unit (control unit). • LHD models: Refer to BRC-217, "LHD : Removal and Installation" • RHD models: Refer to BRC-220, "RHD : Removal and Installation" . 3. CHECK VDC OFF INDICATOR LAMP SIGNAL (2) With CONSULT Check that data monitor displays “On” or “Off” each time when VDC OFF switch is operated. Is the inspection result normal? YES >> Replace the combination meter. Refer to MWI-151, "Removal and Installation" NO >> Check the VDC OFF switch system. Refer to BRC-191, "Diagnosis Procedure" . |