Nissan X-Trail 32. Manual - part 1616

 

  Главная      Nissan     Nissan X-Trail 32 - Service Manual

 

поиск по сайту            

 

 

 

 

 

 

 

 

 

содержание   ..  1614  1615  1616  1617   ..

 

 

Nissan X-Trail 32. Manual - part 1616

 

 

MWI-146

< SYMPTOM DIAGNOSIS >

THE STEERING SWITCHES ARE INOPERATIVE

THE STEERING SWITCHES ARE INOPERATIVE

Description

INFOID:0000000010715034

If any of the following malfunctions is found for the steering switch operation.
• All switches are inoperative
• The specified switch cannot be operated

Diagnosis Procedure

INFOID:0000000010715035

1.

CHECK STEERING SWITCH SIGNAL A CIRCUIT

Check the steering switch signal A circuit. Refer to 

MWI-130, "Diagnosis Procedure"

.

Is the inspection result normal?

YES

>> GO TO 2.

NO

>> Repair or replace malfunctioning parts.

2.

CHECK STEERING SWITCH SIGNAL B CIRCUIT

Check the steering switch signal B circuit. Refer to 

MWI-132, "Diagnosis Procedure"

.

Is the inspection result normal?

YES

>> Replace combination meter. Refer to 

MWI-151, "Removal and Installation"

.

NO

>> Repair or replace malfunctioning parts.

MWI

THE METER CONTROL SWITCH IS INOPERATIVE

MWI-147

< SYMPTOM DIAGNOSIS >

C

D

E

F

G

H

I

J

K

L

M

B

A

O

P

THE METER CONTROL SWITCH IS INOPERATIVE

Description

INFOID:0000000010715036

If any of the following malfunctions is found for the meter control switch operation.
• All switches are inoperative
• The specified switch cannot be operated

Diagnosis Procedure

INFOID:0000000010715037

1.

CHECK METER CONTROL SWITCH SIGNAL CIRCUIT

Check the meter control switch signal circuit. Refer to 

MWI-134, "Diagnosis Procedure"

Is the inspection result normal?

YES

>> GO TO 2.

NO

>> Repair harness or connector.

2.

CHECK METER CONTROL SWITCH

Perform a unit check for the meter control switch. Refer to 

MWI-135, "Component Inspection"

Is the inspection result normal?

YES

>> Replace combination meter. Refer to 

MWI-151, "Removal and Installation"

.

NG

>> Replace meter control switch. Refer to 

MWI-155, "Removal and Installation"

.

MWI-148

< SYMPTOM DIAGNOSIS >

THE DOOR OPEN WARNING CONTINUES DISPLAYING, OR DOES NOT DIS-

PLAY

THE DOOR OPEN WARNING CONTINUES DISPLAYING, OR DOES NOT
DISPLAY

Description

INFOID:0000000010715038

• The door ajar warning is displayed even though all of the doors are closed.
• The door ajar warning is not displayed even though a door is ajar.

Diagnosis Procedure

INFOID:0000000010715039

1.

CHECK DOOR SWITCH CIRCUIT

Connect CONSULT and check the BCM input signals. Refer to 

DLK-186, "Component Function Check"

(TYPE1), 

DLK-495, "Component Function Check"

 (TYPE2), 

DLK-695, "Component Function Check"

(TYPE3), or 

DLK-842, "Component Function Check"

 (TYPE4).

Is the inspection result normal?

YES

>> GO TO 2.

NO

>> Repair or replace malfunctioning parts.

2.

CHECK COMBINATION METER INPUT SIGNAL

Select the “Data Monitor” for the “METER/M&A” and check the “DOOR W/L” monitor value.

Is the inspection result normal?

YES

>> Replace combination meter. Refer to 

MWI-151, "Removal and Installation"

.

NO

>> Replace BCM. Refer to 

BCS-121, "Removal and Installation"

.

“DOOR W/L”

Door open

: On

Door closed

: Off

MWI

THE AMBIENT TEMPERATURE DISPLAY IS INCORRECT

MWI-149

< SYMPTOM DIAGNOSIS >

C

D

E

F

G

H

I

J

K

L

M

B

A

O

P

THE AMBIENT TEMPERATURE DISPLAY IS INCORRECT

Description

INFOID:0000000010715040

• The displayed ambient air temperature is higher than the actual temperature.
• The displayed ambient air temperature is lower than the actual temperature.

Diagnosis Procedure

INFOID:0000000010715041

NOTE:
Check that the symptom is not applicable to the normal operating condition before starting diagnosis. Refer to

MWI-150, "INFORMATION DISPLAY : Description"

.

1.

CHECK AMBIENT SENSOR SIGNAL CIRCUIT

Check the ambient sensor signal circuit. Refer to 

MWI-142, "Diagnosis Procedure"

.

Is the inspection result normal?

YES

>> GO TO 2.

NO

>> Repair or replace malfunctioning parts.

2.

CHECK COMBINATION METER INPUT SIGNAL

Select the “Data Monitor” for the “METER/M&A” and check the “OUTSIDE TEMP” monitor value.

Is the inspection result normal?

YES

>> Replace combination meter. Refer to 

MWI-151, "Removal and Installation"

.

NO

>> Replace ambient sensor. Refer to 

MWI-156, "Removal and Installation"

.

 

 

 

 

 

 

 

содержание   ..  1614  1615  1616  1617   ..