Mitsubishi Outlander (2013+). Manual - part 218

 

  Index      Mitsubishi     Mitsubishi Outlander - service repair manual 2013 year

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  216  217  218  219   ..

 

 

Mitsubishi Outlander (2013+). Manual - part 218

 

 

ETACS

CHASSIS ELECTRICAL

54A-54

CUSTOMISATION FUNCTION

M2545400400953

By operating the M.U.T.-III ETACS system, the fol-
lowing functions can be customised. The pro-
grammed information is held even when the battery 
is disconnected.

Adjustment 
item (M.U.T.-III 
display)

Adjustment item

Adjusting content 
(M.U.T.-III display)

Adjusting content

Turn power 
source

Adjustment of 
turn-signal lamp 
operation condition

ACC or IG1

Operable with ACC or ON position

IG1

Operable with ON position (initial 
condition)

Comfort flasher

With/without 
comfort flasher 
function

Disable

No function

Enable

With function (initial condition)

Hazard answer 
back

Adjustment of the 
number of keyless 
hazard warning 
lamp answer back 
flashes

Lock:1, Unlock:2

LOCK: Flashes once, UNLOCK: Flashes 
twice (initial condition)

Lock:1, Unlock:0

LOCK: Flashes once, UNLOCK: No flash

Lock:0, Unlock:2

LOCK: No flash, UNLOCK: Flash twice

Lock:2, Unlock:1

LOCK: Flash twice, UNLOCK: Flash once

Lock:2, Unlock:0

LOCK: Flash twice, UNLOCK: No flash

Lock:0, Unlock:1

LOCK: No flash, UNLOCK: Flash once

Lock:0, Unlock:0

No function

Front wiper 
operation

Adjustment of the 
intermittent 
windshield wiper 
operation <vehicles 
without lighting 
control sensor or 
vehicles without 
LDW>

Normal INT

Intermittent wiper interval is fixed to 4 
seconds.

Variable INT

Intermittent wiper interval is calculated only 
by the wiper volume control.

Speed Sensitive

Intermittent wiper interval is calculated 
according to the intermittent wiper volume 
control and vehicle speed (initial 
condition).

Adjustment of the 
intermittent 
windshield wiper 
operation <vehicles 
with lighting control 
sensor or vehicles 
with LDW>

Normal INT

Intermittent wiper interval is fixed to 4 
seconds.

Variable INT

Intermittent wiper interval is calculated only 
by the wiper volume control.

Speed Sensitive

Intermittent wiper interval is calculated 
according to the intermittent wiper volume 
control and vehicle speed.

Rain Sensitive

Intermittent wiper interval is calculated 
according to the intermittent wiper volume 
control and lighting control sensor (initial 
condition).

Downloaded from 

www.Manualslib.com

 

manuals search engine

 

ETACS

CHASSIS ELECTRICAL

54A-55

Front/rear wiper 
washer

Disabling or 
enabling 
washer-linked wiper 
function

Only Washer

No function

Washer & Wiper

With function: Without delayed finishing 
wipe function <Initial condition (vehicles for 
RUSSIA)>

With after wipe

With function: With delayed finishing wipe 
function <Initial condition (except vehicles 
for RUSSIA)>

Intermittent time 
of rear wiper

Adjustment of rear 
wiper interval

0 sec.

No wiper interval

4 sec.

4 seconds

8 sec.

8 seconds (initial condition)

16 sec.

16 seconds

Rear wiper Low 
speed mode

Disabling or 
enabling rear wiper 
continuous 
operation

Disable

No function

Enable

With function (initial condition)

Auto fold mirror

Electric folding door 
mirror automatic 
unfolding function 
<vehicles with 
electric retractable 
remote controlled 
door mirrors>

Not Auto

No synchronised operation

Open Vehicle SPD

Vehicle speed-dependent operation

Open/Close by IG

Ignition switch linked operation

OPN/CLS Keyless

Keyless entry linked operation (initial 
condition)

Sensitivity for 
auto lamp

Photo sensor 
sensitivity 
(illumination 
intensity) <vehicles 
with photo sensor>

Level 1 bright

High ambient brightness

Level 2 bright

Standard ambient brightness (initial 
condition)

Level 3

Low ambient brightness

Level 4 dark

Low-low ambient brightness

Lighting control 
sensor sensitivity 
(illumination 
intensity) <vehicles 
with lighting control 
sensor or vehicles 
with LDW>

Level 1 bright

High-high ambient brightness

Level 2 bright

High ambient brightness

Level 3

Standard ambient brightness (initial 
condition)

Level 4 dark

Low ambient brightness

Level 5 dark

Low-low ambient brightness

Auto lamp 
linked wiper

Presence of 
wiper-linked auto 
lamp function 
<vehicles with 
photo sensor>

Disable

No function (initial condition)

Enable

With function

Adjustment 
item (M.U.T.-III 
display)

Adjustment item

Adjusting content 
(M.U.T.-III display)

Adjusting content

Downloaded from 

www.Manualslib.com

 

manuals search engine

 

ETACS

CHASSIS ELECTRICAL

54A-56

Room lamp 
delay timer with 
door

Adjustment of 
interior lamp delay 
shutdown time

0 sec.

0 second (no delay shutdown time)

7.5 sec.

7.5 seconds

15 sec.

15 seconds (initial condition)

30 sec.

30 seconds

60 sec.

60 seconds

120 sec.

120 seconds

180 sec.

180 seconds

Head lamp auto 
cut customise

Adjustment of 
headlamp 
automatic shutdown 
function

Disable

No function

Enable (B-spec.)

With function (initial condition)

Interior lamp 
auto cut timer

Adjustment of 
interior lamp 
automatic shutdown 
function operation 
time

Disable

No function

3 min

3 minutes

30 min

30 minutes (initial condition)

60 min

60 minutes

Comfort flasher 
switch time

Switch operation 
time to activate the 
comfort flasher 
function

Normal

0.4 second (initial condition)

Long

0.8 second

Intelligent/Comf
ort washer

With/without 
Comfort washer 
function

Disable

No function <Initial condition (vehicles for 
RUSSIA)>

Enable

With function <Initial condition (except 
vehicles for RUSSIA)>

Auto door 
unlock

Adjustment of the 
auto door unlock 
function

Disable

Without function <M/T, A/T, CVT> (initial 
condition)

Always (P pos)

With function: Operates when the shift 
lever or the selector lever is moved to the 
P position. <A/T, CVT>

Always(Lock pos)

With function: Operates when the ignition 
switch is moved to the LOCK (OFF) 
position. <M/T, A/T, CVT>

Door unlock 
mode

Adjustment of 
power door locks 
with selective 
unlocking <Vehicles 
without dead lock 
system>

All Doors Unlock

Without function: The first operation of 
keyless entry system or unlock operation 
by KOS unlocks all doors (initial condition).

Dr Door Unlock

With function: The first operation of 
keyless entry system or unlock operation 
by KOS unlocks the driver's door only, and 
the second unlock operation within 2 
seconds after that unlocks all doors. 

Deadlock 
Button 
Operation

Adjustment of the 
dead lock system 
setting procedure 
<vehicles with dead 
lock system>

Twice

Operate the lock switch of the keyless 
entry system or KOS twice.(initial 
condition)

Once

Operate the lock switch of the keyless 
entry system or KOS once.

Adjustment 
item (M.U.T.-III 
display)

Adjustment item

Adjusting content 
(M.U.T.-III display)

Adjusting content

Downloaded from 

www.Manualslib.com

 

manuals search engine

 

ETACS

CHASSIS ELECTRICAL

54A-57

Timer lock timer Timer lock period 

adjustment

30 sec.

30 seconds (initial condition)

60 sec.

60 seconds

120 sec.

120 seconds

180 sec.

180 seconds

Alarm

Enables/disables 
security alarm 
<Vehicles with 
security alarm>

Disable

Without function

Enable

With function (initial condition)

Duration of 
pre-alarm

Adjustment of 
pre-alarm (interior 
alarm) continue 
time <Vehicles with 
security alarm 
(vehicles without 
security alarm 
sensor)>

10 sec.

10 seconds (initial condition)

6 sec.

6 seconds

Multi mode

Multi-mode keyless 
entry function 
customisation 
<Vehicles with 
electric retractable 
remote controlled 
door mirrors>

Disable

No function

D/M: O&C

Door mirror fold/unfold operation only 
(initial condition)

Rear 
wiper(linked 
reverse gear)

Adjustment of 
automatic rear 
window wiper 
operation with 
reverse gear 
engaged

Enable(R wip.ON)

Operates only when the rear wiper switch 
is ON.

Enable(R/F wip.)

Operates only when the front or rear wiper 
switch is ON (initial condition).

KOS key detect 
out from window

With/without KOS 
key exterior 
detection function 
<Vehicles with 
KOS>

Enable

No function

Disable

With function (initial condition)

KOS feature

KOS function 
adjustment 
<Vehicles with 
KOS>

Both enable

All KOS functions are enabled (initial 
condition).

Door Entry enable

Only door entry function is enabled.

ENG start enable

Only engine starting function is enabled.

Both disable

All KOS functions are disabled.

KOS unlock 
disable time

Adjusts the door 
unlock inhibition 
period after door 
lock is activated. 
<Vehicles with 
KOS>

0 sec.

0 second

3 sec.

3 seconds (Initial condition)

5 sec.

5 seconds

Adjustment 
item (M.U.T.-III 
display)

Adjustment item

Adjusting content 
(M.U.T.-III display)

Adjusting content

Downloaded from 

www.Manualslib.com

 

manuals search engine

 

 

 

 

 

 

 

 

Content   ..  216  217  218  219   ..