Mitsubishi Galant 9G. Manual - part 231

 

  Index      Mitsubishi     Mitsubishi Galant 9G - service repair manual

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  229  230  231  232   ..

 

 

Mitsubishi Galant 9G. Manual - part 231

 

 

NOTES

55A-1

GROUP 55A

HEATER, AIR 

CONDITIONING AND 

VENTILATION

CONTENTS

GENERAL DESCRIPTION. . . . . . . . .

55A-3

SERVICE PRECAUTIONS. . . . . . . . .

55A-5

CAUTION LABELS . . . . . . . . . . . . . . . . . . . 

55A-5

MANUAL A/C DIAGNOSIS . . . . . . . .

55A-5

INTRODUCTION TO HEATER, AIR 
CONDITIONING AND VENTILATION 
DIAGNOSIS  . . . . . . . . . . . . . . . . . . . . . . . . 

55A-5

HEATER, AIR CONDITIONING AND 
VENTILATION DIAGNOSTIC 
TROUBLESHOOTING STRATEGY . . . . . . 

55A-5

DIAGNOSTIC FUNCTION . . . . . . . . . . . . . 

55A-6

DIAGNOSTIC TROUBLE CODE CHART 
<LOW TYPE> . . . . . . . . . . . . . . . . . . . . . . . 

55A-10

DIAGNOSTIC TROUBLE CODE 
PROCEDURES <LOW TYPE>. . . . . . . . . . 

55A-11

DIAGNOSTIC TROUBLE CODE CHART 
<MIDDLE TYPE> . . . . . . . . . . . . . . . . . . . . 

55A-58

DIAGNOSTIC TROUBLE CODE 
PROCEDURES <MIDDLE TYPE> . . . . . . . 

55A-11

SYMPTOM CHART <LOW TYPE>. . . . . . . 

55A-110

SYMPTOM PROCEDURES <LOW TYPE> 

55A-110

SYMPTOM CHART <MIDDLE TYPE> . . . . 

55A-178

SYMPTOM PROCEDURES 
<MIDDLE TYPE> . . . . . . . . . . . . . . . . . . . . 

55A-110

DATA LIST REFERENCE TABLE . . . . . . . . 

55A-250

ACTUATOR TEST REFERENCE . . . . . . . . 

55A-252

CHECK  AT A/C-ECU TERMINAL 
<LOW TYPE>  . . . . . . . . . . . . . . . . . . . . . . . 

55A-253

CHECK  AT A/C-ECU TERMINAL 
<MIDDLE TYPE>  . . . . . . . . . . . . . . . . . . . . 

55A-255

SPECIAL TOOLS . . . . . . . . . . . . . . . .

55A-257

ON-VEHICLE SERVICE . . . . . . . . . . .

55A-259

REFRIGERANT LEVEL TEST  . . . . . . . . . . 

55A-259

A/C COMPRESSOR CLUTCH TEST  . . . . . 

55A-259

SIMPLE INSPECTION OF THE A/C 
PRESSURE SENSOR. . . . . . . . . . . . . . . . . 

55A-259

COMPRESSOR DRIVE BELT 
ADJUSTMENT  . . . . . . . . . . . . . . . . . . . . . . 

55A-260

CHARGING . . . . . . . . . . . . . . . . . . . . . . . . . 

55A-260

PERFORMANCE TEST  . . . . . . . . . . . . . . . 

55A-261

REFRIGERANT LEAK REPAIR 
PROCEDURE  . . . . . . . . . . . . . . . . . . . . . . . 

55A-262

COMPRESSOR NOISE CHECK . . . . . . . . . 

55A-262

POWER RELAY CHECK. . . . . . . . . . . . . . . 

55A-263

IDLE-UP OPERATION CHECK . . . . . . . . . . 

55A-264

Continued on next page

55A-2

HEATER CONTROL ASSEMBLY AND 
A/C SWITCH  . . . . . . . . . . . . . . . . . . .

55A-266

REMOVAL AND INSTALLATION . . . . . . . . 

55A-266

INSPECTION . . . . . . . . . . . . . . . . . . . . . . . 

55A-266

HEATER UNIT, HEATER CORE, 
BLOWER ASSEMBLY AND 
EVAPORATOR UNIT. . . . . . . . . . . . .

55A-267

REMOVAL AND INSTALLATION . . . . . . . . 

55A-267

REMOVAL AND INSTALLATION . . . . . . . . 

55A-269

DISASSEMBLY AND ASSEMBLY . . . . . . . 

55A-270

INSPECTION . . . . . . . . . . . . . . . . . . . . . . . 

55A-271

BLOWER ASSEMBLY DISASSEMBLY 
AND ASSEMBLY . . . . . . . . . . . . . . . . . . . . 

55A-272

MOTORS AND TRANSISTOR. . . . . .

55A-273

REMOVAL AND INSTALLATION . . . . . . . . 

55A-273

INSPECTION . . . . . . . . . . . . . . . . . . . . . . . 

55A-274

AMBIENT TEMPERATURE 
SENSOR. . . . . . . . . . . . . . . . . . . . . . .

55A-276

REMOVAL AND INSTALLATION . . . . . . . . 

55A-276

INSPECTION . . . . . . . . . . . . . . . . . . . . . . . 

55A-277

COMPRESSOR ASSEMBLY AND 
TENSION PULLEY . . . . . . . . . . . . . . .

55A-277

REMOVAL AND INSTALLATION . . . . . . . . 

55A-277

INSPECTION. . . . . . . . . . . . . . . . . . . . . . . . 

55A-279

DISASSEMBLY AND ASSEMBLY  . . . . . . . 

55A-280

INSPECTION. . . . . . . . . . . . . . . . . . . . . . . . 

55A-282

CONDENSER AND CONDENSER 
FAN MOTOR. . . . . . . . . . . . . . . . . . . .

55A-283

REMOVAL AND INSTALLATION . . . . . . . . 

55A-283

INSPECTION. . . . . . . . . . . . . . . . . . . . . . . . 

55A-284

REFRIGERANT LINE . . . . . . . . . . . . .

55A-285

REMOVAL AND INSTALLATION . . . . . . . . 

55A-285

DUCTS  . . . . . . . . . . . . . . . . . . . . . . . .

55A-287

REMOVAL AND INSTALLATION . . . . . . . . 

55A-287

VENTILATORS . . . . . . . . . . . . . . . . . .

55A-288

REMOVAL AND INSTALLATION . . . . . . . . 

55A-288

SPECIFICATIONS  . . . . . . . . . . . . . . .

55A-289

FASTENER TIGHTENING 
SPECIFICATIONS. . . . . . . . . . . . . . . . . . . . 

55A-289

GENERAL SPECIFICATIONS  . . . . . . . . . . 

55A-289

SERVICE SPECIFICATIONS  . . . . . . . . . . . 

55A-289

LUBRICANTS  . . . . . . . . . . . . . . . . . . . . . . . 

55A-289

GENERAL DESCRIPTION

TSB Revision

HEATER, AIR CONDITIONING AND VENTILATION

55A-3

GENERAL DESCRIPTION

M1552000100500

The heater and cooling units are combined in a sin-
gle unit, which, with the mode film damper and flow 
rate control valve in the heater unit, reduces ventila-
tion resistance, increases fan power, and decreases 
noise. 

SAFETY PRECAUTIONS

WARNING

Wear safety goggles and gloves when servic-
ing the refrigeration system to prevent 
severe damage to eyes and hands.

Because R-134a refrigerant is a hydro fluorocarbon 
(HFC) which contains hydrogen atoms in place of 
chlorine atoms, it will not cause damage to the ozone 
layer.
Ozone filters out harmful radiation from the sun. To 
assist in protecting the ozone layer, Mitsubishi 
Motors Corporation recommends an R-134a refriger-
ant recycling device.
Refrigerant R-134a is transparent and colorless in 
both the liquid and vapor state. Since it has a boiling 
point of 

−29.8°C (−21.64°F) at atmospheric pressure, 

it will be a vapor at all normal temperatures and pres-
sures. The vapor is heavier than air, non-flammable, 
and non-explosive. The following precautions must 
be observed when handling R-134a.

WARNING

Do not heat R-134a above 40

°

C (104.0

°

F) or it 

may catch fire and explode.

R-134a evaporates so rapidly at normal atmospheric 
pressures and temperatures that it tends to freeze 
anything it contacts. For this reason, extreme care 
must be taken to prevent any liquid refrigerant from 
contacting the skin and especially the eyes. Always 
wear safety goggles when servicing the refrigeration 
part of the A/C system. Keep a bottle of sterile min-
eral oil handy when working on the refrigeration sys-
tem.

1. Should any liquid refrigerant get into your eyes, 

use a few drops of mineral oil to wash them out. 
R-134a is rapidly absorbed by the oil.

2. Next, splash your eyes with plenty of cold water.
3. Call your doctor immediately even if irritation has 

ceased.

CAUTION

Keep R-134a containers upright when charging 
the system.
In most instances, moderate heat is required to bring 
the pressure of the refrigerant in its container above 
the pressure of the system when charging or adding 
refrigerant.
A bucket or large pan of hot water not over 40

°C 

(104.0

°F) is all the heat required for this purpose. Do 

not heat the refrigerant container with a blow torch or 
any other means that would raise temperature and 
pressure above this temperature. Do not weld or 
steam-clean on or near the system components or 
refrigerant lines.

WARNING

The leak detector for R-134a should be used 
to check for refrigerant gas leaks.

CAUTION

Do not allow liquid refrigerant to touch bright 
metal or it will be stained.
When metering R-134a into the refrigeration system, 
keep the supply tank or cans in an upright position. If 
the refrigerant container is on its side or upside 
down, liquid refrigerant will enter the system and 
damage the compressor.
Refrigerant will tarnish bright metal and chrome sur-
faces, and in combination with moisture can severely 
corrode all metal surfaces.

ITEM

SPECIFICATION

Heater control assembly

Dial type

Compressor

MSC105CA

Compressor Model

Scroll type

Refrigerant and quantity g (oz)

R-134a (HFC-134a), 590 

− 630 (20.80 − 22.22)

 

 

 

 

 

 

 