Symptom List: P1696-EEPROM MEMORY WRITE DENIED/INVALID Test Note: All symptoms listed above are diagnosed using the same tests. The title for the tests will be P1696-EEPROM MEMORY When Monitored and Set Condition: P1696-EEPROM MEMORY WRITE DENIED/INVALID When Monitored: With the ignition on continuous. Set Condition: An attempt to program/write to the internal EEPROM failed. Also checks at power down. P1697-EMR (SRI) MILEAGE NOT STORED When Monitored: With the ignition on continuous. Set Condition: An attempt to program/write to the internal EEPROM failed, Also checks at power down. POSSIBLE CAUSES DRB DISPLAYS WRITE FAILURE DRB DISPLAYS WRITE REFUSED 2ND TIME DRB DISPLAYS SRI MILEAGE INVALID COMPARE SRI MILEAGE WITH ODOMETER TEST ACTION APPLICABILITY 1 With the DRBIII t, perform the SRI Memory Test. Does the DRBIII t display Write Failure? All Yes → Replace and program the Powertrain Control Module in accor- dance with the Service Information. No → Go To 2 2 With the DRBIII t, perform the SRI Memory Test. Does the DRBIII t display Write Refused? All Yes → Go To 3 No → Go To 4 277 DRIVEABILITY - NGC |