CF65/75/85 series ≥0E621376

Safety instructions

BATTERIES

1-1

1. SAFETY INSTRUCTIONS

1.1 BATTERIES

-

The sulphuric acid in the batteries is an

aggressive and poisonous liquid. While

working on batteries, wear protective

clothing, gloves and safety goggles.

In case of contact with clothes, skin or eyes,

wash immediately with copious amounts of

water. Consult a doctor in case of contact

with the eyes or skin.

-

Always remove the earth lead first before

working on batteries.

When connecting battery leads, always

connect the earth lead last.

-

Always handle batteries carefully and hold

them upright.

-

When topping up batteries, never allow the

electrolyte level to rise more than 10 mm

above the plates or above the level

indicator.

-

Never put tools or other materials, which

could accidentally short circuit the battery

poles, down on the batteries or in the

vicinity of batteries. Short-circuited battery

poles may cause the battery to explode.

-

Secure the batteries well after completing

the work, but not too tightly.

4

 200404

5

BATTERIES

Safety instructions

CF65/75/85 series ≥0E621376

1-2

1.2 BATTERY CHARGING

-

An explosive gas mixture may be released

during battery charging. Only charge

batteries in a well-ventilated area.

-

Never smoke or allow naked flames or

sparks in the vicinity of the battery.

-

Allow frozen batteries to thaw before

charging.

-

Switch the charger off before the leads to

the battery are disconnected.

4

 200404

5

CF65/75/85 series ≥0E621376

Charging batteries

BATTERIES

2-1

2. CHARGING BATTERIES

2.1 GENERAL

-

A battery may only be charged using DC

current. Connect the positive pole of the

battery to the positive terminal (+) of the

charger, and the negative pole of the battery

to the negative terminal (--) of the charger.

The cell sealing plugs may remain on the

battery during charging (with the exception

of fast charging).

The cell voltage will rise during charging.

This increase in voltage depends on the

charging current applied and the

temperature. During normal charging, the

cell voltage will rise from about 2 volts/cell

to about 2.65 volts/cell. If a charging voltage

of about 2.35 to 2.4 volts/cell (about 14.2

volts in a 12V battery) is exceeded, this will

initiate active gas development.

As a consequence of the rise in voltage

during charging, the charging current will

gradually fall, as a rule.

Overcharging will reduce the service life of

a battery.

-

If the charging of the battery is continued

after it has been fully charged (even with a

low current), this will lead to corrosion

(corrosive attack) of the grids of the positive

battery plates. This type of wear leads to

premature redundancy of the battery.

Depending on the capacity of the charger,

the normal charging time is between 8 and

15 hours.

If during charging, the temperature of the

battery acid exceeds 55_C, charging should

be stopped. High temperatures reduce the

service life of the battery.

4

 200404

5

BATTERIES

Charging batteries

CF65/75/85 series ≥0E621376

2-2

-

A battery should be considered to be

charged when the charge voltage stops

rising for a period 2 hours and the acid

density (relative density) has reached the

nominal value (for example 1.28 kg/dm

3

)

and it rises no further.

-

A charged battery must be used

immediately. If this is not possible, maintain

the battery as described in the “Storage of

batteries” section.

-

A discharged battery must be charged as

soon as possible. If a discharged battery is

not recharged, the battery plates may

become sulphated (i.e. they may become

hard), which will lead to permanent loss of

capacity.

-

Never disconnect the battery terminals

when the engine is running to prevent

damage to electronic components.

-

Connect the positive lead (+) of the battery

charger to the positive terminal (+) of the

battery first and then the negative lead (--)

to the negative terminal (--).

-

Switch off the battery charger before

disconnecting the battery charger leads, to

avoid sparking and to eliminate the risk of

explosion.

-

To disconnect, release the negative terminal

(--) first and then the positive terminal (+).