Opel Frontera UBS. Manual - part 2098

 

  Index      Opel     Opel Frontera UBS - service repair manual 1998-2002 year

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  2096  2097  2098  2099   ..

 

 

Opel Frontera UBS. Manual - part 2098

 

 

ENGINE ELECTRICAL

6D1–3

a. VOLTAGE DOES NOT DROP BELOW THE

MINIMUM LISTED IN THE TABLE – The battery is
good and should be returned to service.

b. VOLTAGE IS LESS THAN MINIMUM LISTED –

Replace battery.

ESTIMATED TEMPERATURE

MINIMUM

VOLTAGE

°

F

°

C

V

70

21

9.6

60

16

9.5

50

10

9.4

40

4

9.3

30

–1

9.1

20

–7

8.9

10

–12

8.7

0

–18

8.5

The battery temperature must be estimated by feel

and by the temperature the battery has been

exposed to for the preceding few hours.

Battery Charging

Observe the following safety precautions when charging
the battery:

1. Never attempt to charge the battery when the fluid

level is below the lower level line on the side of the
battery. In this case, the battery must be replaced.

2. Pay close attention to the battery during charging

procedure.
Battery charging should be discontinued or the rate of
charge reduced if the battery feels hot to the touch.
Battery charging should be discontinued or the rate of
charge reduced if the battery begins to gas or spew
electrolyte from the vent holes.

3. In order to more easily view the hydrometer blue dot

or ring, it may be necessary to jiggle or tilt the battery.

4. Battery temperature can have a great effect on

battery charging capacity.

5. The sealed battery used on this vehicle may be either

quick charged or slow charged in the same manner as
other batteries.
Whichever method you decide to use, be sure that
you completely charge the battery. Never partially
charge the battery.

Jump Starting

Jump Starting with an Auxiliary (Booster)
Battery

CAUTION: Never push or tow the vehicle in an
attempt to start it. Serious damage to the emission
system as well as other vehicle parts will result.

Treat both the discharged battery and the booster
battery with great care when using jumper cables.
Carefully follow the jump starting procedure, being
careful at all times to avoid sparking.

WARNING: FAILURE TO CAREFULLY FOLLOW THE
JUMP STARTING PROCEDURE COULD RESULT IN
THE FOLLOWING:

1. Serious personal injury, particularly to your eyes.
2. Property damage from a battery explosion, battery

acid, or an electrical fire.

3. Damage to the electronic components of one or both

vehicles particularly.

Never expose the battery to an open flame or electrical
spark. Gas generated by the battery may catch fire or
explode.
Remove any rings, watches, or other jewelry before
working around the battery. Protect your eyes by wearing
an approved set of goggles.
Never allow battery fluid to come in contact with your eyes
or skin.
Never allow battery fluid to come in contact with fabrics or
painted surfaces.
Battery fluid is a highly corrosive acid.
Should battery fluid come in contact with your eyes, skin,
fabric, or a painted surface, immediately and thoroughly
rinse the affected area with clean tap water.
Never allow metal tools or jumper cables to come in
contact with the positive battery terminal, or any other
metal surface of the vehicle. This will protect against a
short circuit.
Always keep batteries out of reach of young children.

Jump Starting Procedure

1. Set the vehicle parking brake.

If the vehicle is equipped with an automatic
transmission, place the selector level in the “PARK”
position.
If the vehicle is equipped with a manual transmission,
place the shift lever in the “NEUTRAL” position.
Turn “OFF” the ignition.
Turn “OFF” all lights and any other accessory
requiring electrical power.

2. Look at the built–in hydrometer.

If the indication area of the built–in hydrometer is
completely clear, do not try to jump start.

3. Attach the end of one jumper cable to the positive

terminal of the booster battery.
Attach the other end of the same cable to the positive
terminal of the discharged battery.
Do not allow the vehicles to touch each other. This will
cause a ground connection, effectively neutralizing
the charging procedure.
Be sure that the booster battery has a 12 volt rating.

6D1–4

ENGINE ELECTRICAL

4. Attach one end of the remaining cable to the negative

terminal of the booster battery.
Attach the other end of the same cable to a solid
engine ground (such as the air conditioning
compressor bracket or the generator mounting
bracket) of the vehicle with the discharged battery.
The ground connection must be at least 450 mm (18
in.) from the battery of the vehicle whose battery is
being charged.

WARNING: NEVER ATTACH THE END OF THE
JUMPER CABLE DIRECTLY TO THE NEGATIVE
TERMINAL OF THE DEAD BATTERY.

5. Start the engine of the vehicle with the good battery.

Make sure that all unnecessary electrical accessories
have been turned “OFF”.

6. Start the engine of the vehicle with the dead battery.
7. To remove the jumper cables, follow the above

directions in reverse order.
Be sure to first disconnect the negative cable from the
vehicle with the discharged battery.

Battery Removal

061RS002

1. Remove negative cable (1).
2. Remove positive cable (2).
3. Remove retainer screw and rods (3).
4. Remove retainer (4).
5. Remove battery (5).

Battery Installation

1. Install battery (5).
2. Install retainer (4).
3. Instal retainer screw and rods (3).

NOTE: Make sure that the rod is hooked on the body
side.

4. Install positive cable (2).
5. Install negative cable (1).

ENGINE ELECTRICAL

6D1–5

Main Data and Specifications

General Specifications

Model  (JIS)

95D31R–MF

80D26R–MF

75D26R–MF

Voltage  (V)

12

12

12

Cold Cranking Performance  (Amp)

622

582

490

Reserve Capacity  (Min)

159

133

123

Load Test  (Amp)

310

290

245

Fast Charge Maximum Amperage  (Amp)

20

20

20

BCI Group No.

27

24

24

6D1–6

ENGINE ELECTRICAL

MEMO

 

 

 

 

 

 

 