Nissan Quest E52. Manual - part 407

 

  Index      Nissan     Nissan Quest E52 (2011-2014 year) - Service and Repair Manual

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  405  406  407  408   ..

 

 

Nissan Quest E52. Manual - part 407

 

 

DLK-342

< DTC/CIRCUIT DIAGNOSIS >

SLIDING DOOR OPEN/CLOSE SWITCH

3.

Check voltage between sliding door open/close switch (front side) harness connector and ground.

Is the inspection result normal?

YES

>> GO TO 3.

NO

>> GO TO 2.

2.

CHECK SLIDING DOOR OPEN/CLOSE SWITCH CIRCUIT

1.

Disconnect sliding door control unit RH connector.

2.

Check continuity between sliding door control unit RH harness connector and sliding door open/close
switch (front side) harness connector.

3.

Check continuity between sliding door control unit RH harness connector and ground.

Is the inspection result normal?

YES

>> Replace sliding door control unit RH. Refer to 

DLK-500, "RH : Removal and Installation"

.

NO

>> Repair or replace harness.

3.

CHECK SLIDING DOOR OPEN/CLOSE SWITCH GROUND CIRCUIT

Check continuity between sliding door open/close switch (front side) harness connector and ground.

Is the inspection result normal?

YES

>> GO TO 4.

NO

>> Repair or replace harness.

4.

CHECK SLIDING DOOR OPEN/CLOSE SWITCH

Refer to 

DLK-342, "FRONT RH : Component Inspection"

.

Is the inspection result normal?

YES

>> GO TO 5.

NO

>> Replace sliding door open/close switch (front side).

5.

CHECK INTERMITTENT INCIDENT

Refer to 

GI-42, "Intermittent Incident"

.

>> INSPECTION END

FRONT RH : Component Inspection

INFOID:0000000009649288

1.

CHECK SLIDING DOOR OPEN/CLOSE SWITCH

1.

Turn ignition switch OFF.

2.

Disconnect sliding door open/close switch (front side) connector.

3.

Check continuity between sliding door open/close switch (front side) terminals.

(+)

(–)

Voltage

Sliding door open/close switch (front side)

Connector

Terminal

M90

1

Ground

8 – 16 V

Sliding door control unit RH

Sliding door open/close switch (front side)

Continuity 

Connector

Terminal

Connector

Terminal

B247

19

M90

1

Existed

Sliding door control unit RH

Ground

Continuity 

Connector

Terminal

B247

19

Not existed

Sliding door open/close switch (front side)

Ground

Continuity 

Connector

Terminal

M90

3

Existed

SLIDING DOOR OPEN/CLOSE SWITCH

DLK-343

< DTC/CIRCUIT DIAGNOSIS >

C

D

E

F

G

H

I

J

L

M

A

B

DLK

N

O

P

Is the inspection result normal?

YES

>> INSPECTION END

NO

>> Replace sliding door open/close switch (front side).

REAR LH

REAR LH : Component Function Check

INFOID:0000000009649289

1.

CHECK FUNCTION

1.

Select “AUTO SLDE DOOR” using CONSULT.

2.

Select “B PILLER SW” in “DATA MONITOR” mode.

3.

Check that the function operates normally according to the following conditions.

Is the inspection result normal?

YES

>> Sliding door open/close switch (rear LH) is OK.

NO

>> Refer to 

DLK-343, "REAR LH : Diagnosis Procedure"

.

REAR LH : Diagnosis Procedure

INFOID:0000000009649290

1.

CHECK SLIDING DOOR OPEN/CLOSE SWITCH INPUT SIGNAL

1.

Turn ignition switch OFF.

2.

Disconnect sliding door open/close switch (rear LH) connector.

3.

Check voltage between sliding door open/close switch (rear LH) harness connector and ground.

Is the inspection result normal?

YES

>> GO TO 3.

NO

>> GO TO 2.

2.

CHECK SLIDING DOOR OPEN/CLOSE SWITCH CIRCUIT

1.

Disconnect sliding door control unit LH connector.

2.

Check continuity between sliding door control unit LH harness connector and sliding door open/close
switch (rear LH) harness connector.

3.

Check continuity between sliding door control unit LH harness connector and ground.

Sliding door open/close switch (front side)

Condition

Continuity

Terminal

1

3

Sliding door open/close switch 
(front RH)

Pressed

Existed

Released

Not existed

Monitor item

Condition

Status

B PILLER SW

Sliding door open/close switch 
(rear LH)

Pressed

ON

Released

OFF

(+)

(–)

Voltage

Sliding door open/close switch (rear LH)

Connector

Terminal

B25

1

Ground

8 – 16 V

Sliding door control unit LH

Sliding door open/close switch (rear LH)

Continuity 

Connector

Terminal

Connector

Terminal

B45

2

B25

1

Existed

Sliding door control unit LH

Ground

Continuity 

Connector

Terminal

B45

2

Not existed

DLK-344

< DTC/CIRCUIT DIAGNOSIS >

SLIDING DOOR OPEN/CLOSE SWITCH

Is the inspection result normal?

YES

>> Replace sliding door control unit LH. Refer to 

DLK-500, "LH : Removal and Installation"

.

NO

>> Repair or replace harness.

3.

CHECK SLIDING DOOR OPEN/CLOSE SWITCH GROUND CIRCUIT

Check continuity between sliding door open/close switch (rear LH) harness connector and ground.

Is the inspection result normal?

YES

>> GO TO 4.

NO

>> Repair or replace harness.

4.

CHECK SLIDING DOOR OPEN/CLOSE SWITCH

Refer to 

DLK-344, "REAR LH : Component Inspection"

.

Is the inspection result normal?

YES

>> GO TO 5.

NO

>> Replace sliding door open/close switch (rear LH).

5.

CHECK INTERMITTENT INCIDENT

Refer to 

GI-42, "Intermittent Incident"

.

>> INSPECTION END

REAR LH : Component Inspection

INFOID:0000000009649291

1.

CHECK SLIDING DOOR OPEN/CLOSE SWITCH

1.

Turn ignition switch OFF.

2.

Disconnect sliding door open/close switch (rear LH) connector.

3.

Check continuity between sliding door open/close switch (rear LH) terminals.

Is the inspection result normal?

YES

>> INSPECTION END

NO

>> Replace sliding door open/close switch (rear LH).

REAR RH

REAR RH : Component Function Check

INFOID:0000000009649292

1.

CHECK FUNCTION

1.

Select “AUTO SLDE DOOR RIGHT” using CONSULT.

2.

Select “B PILLER SW” in “DATA MONITOR” mode.

3.

Check that the function operates normally according to the following conditions.

Is the inspection result normal?

YES

>> Sliding door open/close switch (rear RH) is OK.

NO

>> Refer to 

DLK-343, "REAR LH : Diagnosis Procedure"

.

Sliding door open/close switch (rear LH)

Ground

Continuity 

Connector

Terminal

B25

2

Existed

Sliding door open/close switch (rear LH)

Condition

Continuity

Terminal

1

2

Sliding door open/close switch 
(rear LH)

Pressed

Existed

Released

Not existed

Monitor item

Condition

Status

B PILLER SW

Sliding door open/close switch 
(rear RH)

Pressed

ON

Released

OFF

SLIDING DOOR OPEN/CLOSE SWITCH

DLK-345

< DTC/CIRCUIT DIAGNOSIS >

C

D

E

F

G

H

I

J

L

M

A

B

DLK

N

O

P

REAR RH : Diagnosis Procedure

INFOID:0000000009649293

1.

CHECK SLIDING DOOR OPEN/CLOSE SWITCH INPUT SIGNAL

1.

Turn ignition switch OFF.

2.

Disconnect sliding door open/close switch (rear RH) connector.

3.

Check voltage between sliding door open/close switch (rear RH) harness connector and ground.

Is the inspection result normal?

YES

>> GO TO 3.

NO

>> GO TO 2.

2.

CHECK SLIDING DOOR OPEN/CLOSE SWITCH CIRCUIT

1.

Disconnect sliding door control unit RH connector.

2.

Check continuity between sliding door control unit RH harness connector and sliding door open/close
switch (rear RH) harness connector.

3.

Check continuity between sliding door control unit RH harness connector and ground.

Is the inspection result normal?

YES

>> Replace sliding door control unit RH. Refer to 

DLK-500, "RH : Removal and Installation"

.

NO

>> Repair or replace harness.

3.

CHECK SLIDING DOOR OPEN/CLOSE SWITCH GROUND CIRCUIT

Check continuity between sliding door open/close switch (rear RH) harness connector and ground.

Is the inspection result normal?

YES

>> GO TO 4.

NO

>> Repair or replace harness.

4.

CHECK SLIDING DOOR OPEN/CLOSE SWITCH

Refer to 

DLK-346, "REAR RH : Component Inspection"

.

Is the inspection result normal?

YES

>> GO TO 5.

NO

>> Replace sliding door open/close switch (rear RH).

5.

CHECK INTERMITTENT INCIDENT

Refer to 

GI-42, "Intermittent Incident"

.

>> INSPECTION END

(+)

(–)

Voltage

Sliding door open/close switch (rear RH)

Connector

Terminal

B206

1

Ground

8 – 16 V

Sliding door control unit RH

Sliding door open/close switch (rear RH)

Continuity 

Connector

Terminal

Connector

Terminal

B247

2

B206

1

Existed

Sliding door control unit RH

Ground

Continuity 

Connector

Terminal

B247

2

Not existed

Sliding door open/close switch (rear RH)

Ground

Continuity 

Connector

Terminal

B206

2

Existed

 

 

 

 

 

 

 

Content   ..  405  406  407  408   ..