DLK-330

< DTC/CIRCUIT DIAGNOSIS >

CHILD LOCK STATUS SWITCH

CHILD LOCK STATUS SWITCH

SLIDING DOOR LH

SLIDING DOOR LH : Component Function Check

INFOID:0000000009649268

1.

CHECK FUNCTION

1.

Select “AUTO SLDE DOOR” using CONSULT.

2.

Select “CHILD LOCK SW” in “DATA MONITOR” mode.

3.

Check that the function operates normally according to the following conditions.

Is the inspection result normal?

YES

>> Child lock status switch is OK.

NO

>> Refer to 

DLK-330, "SLIDING DOOR LH : Diagnosis Procedure"

.

SLIDING DOOR LH : Diagnosis Procedure

INFOID:0000000009649269

1.

CHECK CHILD LOCK STATUS SWITCH INPUT SIGNAL

1.

Turn ignition switch OFF.

2.

Disconnect remote control assembly LH connector.

3.

Check voltage between remote control assembly LH harness connector and ground.

Is the inspection result normal?

YES

>> GO TO 3.

NO

>> GO TO 2.

2.

CHECK CHILD LOCK STATUS SWITCH CIRCUIT

1.

Disconnect sliding door control unit LH connector.

2.

Check continuity between sliding door control unit LH harness connector and remote control assembly LH
harness connector.

3.

Check continuity between sliding door control unit LH harness connector and ground.

Is the inspection result normal?

YES

>> Replace sliding door control unit LH. Refer to 

DLK-500, "LH : Removal and Installation"

.

NO

>> Repair or replace harness.

3.

CHECK CHILD LOCK STATUS SWITCH GROUND CIRCUIT

1.

Disconnect sliding door control unit LH connector.

2.

Check continuity between sliding door control unit LH harness connector and remote control assembly LH
harness connector.

Monitor item

Condition

Status

CHILD LOCK SW

Child lock LH

LOCK

OFF

UNLOCK

ON

(+)

(–)

Voltage

Remote control assembly LH

Connector

Terminal

D118

4

Ground

8 – 16 V

Sliding door control unit LH

Remote control assembly LH

Continuity 

Connector

Terminal

Connector

Terminal

B45

20

D118

4

Existed

Sliding door control unit LH

Ground

Continuity 

Connector

Terminal

B45

20

Not existed

CHILD LOCK STATUS SWITCH

DLK-331

< DTC/CIRCUIT DIAGNOSIS >

C

D

E

F

G

H

I

J

L

M

A

B

DLK

N

O

P

3.

Check continuity between sliding door control unit LH harness connector and ground.

Is the inspection result normal?

YES

>> GO TO 4.

NO

>> Repair or replace harness.

4.

CHECK CHILD LOCK STATUS SWITCH CIRCUIT 2

1.

Connect sliding door control unit LH connector and remote control assembly LH connector.

2.

Check voltage between sliding door control unit LH harness connector and ground.

Is the inspection result normal?

YES

>> GO TO 5.

NO

>> Replace sliding door control unit LH. Refer to 

DLK-500, "LH : Removal and Installation"

.

5.

CHECK CHILD LOCK STATUS SWITCH

Refer to 

DLK-331, "SLIDING DOOR LH : Component Inspection"

.

Is the inspection result normal?

YES

>> GO TO 6.

NO

>> Replace remote control assembly LH.

6.

CHECK INTERMITTENT INCIDENT

Refer to 

GI-42, "Intermittent Incident"

.

>> INSPECTION END

SLIDING DOOR LH : Component Inspection

INFOID:0000000009649270

1.

CHECK CHILD LOCK STATUS SWITCH

1.

Turn ignition switch OFF.

2.

Disconnect remote control assembly LH connector.

3.

Check continuity between remote control assembly LH terminals.

Is the inspection result normal?

YES

>> INSPECTION END

NO

>> Replace remote control assembly LH.

SLIDING DOOR RH

Sliding door control unit LH

Remote control assembly LH

Continuity 

Connector

Terminal

Connector

Terminal

B45

23

D118

1

Existed

Sliding door control unit LH

Ground

Continuity 

Connector

Terminal

B45

23

Not existed

(+)

(–)

Voltage

Sliding door control unit LH

Connector

Terminal

B45

23

Ground

0 V

Remote control assembly LH

Condition

Continuity

Terminal

4

1

Child lock LH

LOCK

Not existed

UNLOCK

Existed

DLK-332

< DTC/CIRCUIT DIAGNOSIS >

CHILD LOCK STATUS SWITCH

SLIDING DOOR RH : Component Function Check

INFOID:0000000009649271

1.

CHECK FUNCTION

1.

Select “AUTO SLDE DOOR RIGHT” using CONSULT.

2.

Select “CHILD LOCK SW” in “DATA MONITOR” mode.

3.

Check that the function operates normally according to the following conditions.

Is the inspection result normal?

YES

>> Child lock status switch is OK.

NO

>> Refer to 

DLK-332, "SLIDING DOOR RH : Diagnosis Procedure"

.

SLIDING DOOR RH : Diagnosis Procedure

INFOID:0000000009649272

1.

CHECK CHILD LOCK STATUS SWITCH INPUT SIGNAL

1.

Turn ignition switch OFF.

2.

Disconnect remote control assembly RH connector.

3.

Check voltage between remote control assembly RH harness connector and ground.

Is the inspection result normal?

YES

>> GO TO 3.

NO

>> GO TO 2.

2.

CHECK CHILD LOCK STATUS SWITCH CIRCUIT

1.

Disconnect sliding door control unit RH connector.

2.

Check continuity between sliding door control unit RH harness connector and remote control assembly
RH harness connector.

3.

Check continuity between sliding door control unit RH harness connector and ground.

Is the inspection result normal?

YES

>> Replace sliding door control unit RH. Refer to 

DLK-500, "RH : Removal and Installation"

.

NO

>> Repair or replace harness.

3.

CHECK CHILD LOCK STATUS SWITCH GROUND CIRCUIT

1.

Disconnect sliding door control unit RH connector.

2.

Check continuity between sliding door control unit RH harness connector and remote control assembly
RH harness connector.

Monitor item

Condition

Status

CHILD LOCK SW

Child lock RH

LOCK

OFF

UNLOCK

ON

(+)

(–)

Voltage

Remote control assembly RH

Connector

Terminal

D127

4

Ground

8 – 16 V

Sliding door control unit RH

Remote control assembly RH

Continuity 

Connector

Terminal

Connector

Terminal

B247

20

D127

4

Existed

Sliding door control unit RH

Ground

Continuity 

Connector

Terminal

B247

20

Not existed

CHILD LOCK STATUS SWITCH

DLK-333

< DTC/CIRCUIT DIAGNOSIS >

C

D

E

F

G

H

I

J

L

M

A

B

DLK

N

O

P

3.

Check continuity between sliding door control unit RH harness connector and ground.

Is the inspection result normal?

YES

>> GO TO 4.

NO

>> Repair or replace harness.

4.

CHECK CHILD LOCK STATUS SWITCH CIRCUIT 2

1.

Connect sliding door control unit RH connector and remote control assembly RH connector.

2.

Check voltage between sliding door control unit RH harness connector and ground.

Is the inspection result normal?

YES

>> GO TO 5.

NO

>> Replace sliding door control unit RH. Refer to 

DLK-500, "RH : Removal and Installation"

.

5.

CHECK CHILD LOCK STATUS SWITCH

Refer to 

DLK-333, "SLIDING DOOR RH : Component Inspection"

.

Is the inspection result normal?

YES

>> GO TO 6.

NO

>> Replace remote control assembly RH.

6.

CHECK INTERMITTENT INCIDENT

Refer to 

GI-42, "Intermittent Incident"

.

>> INSPECTION END

SLIDING DOOR RH : Component Inspection

INFOID:0000000009649273

1.

CHECK CHILD LOCK STATUS SWITCH

1.

Turn ignition switch OFF.

2.

Disconnect remote control assembly RH connector.

3.

Check continuity between remote control assembly RH terminals.

Is the inspection result normal?

YES

>> INSPECTION END

NO

>> Replace remote control assembly RH.

Sliding door control unit RH

Remote control assembly RH

Continuity 

Connector

Terminal

Connector

Terminal

B247

23

D127

1

Existed

Sliding door control unit RH

Ground

Continuity 

Connector

Terminal

B247

23

Not existed

(+)

(–)

Voltage

Sliding door control unit RH

Connector

Terminal

B247

23

Ground

0 V

Remote control assembly RH

Condition

Continuity

Terminal

4

1

Child lock RH

LOCK

Not existed

UNLOCK

Existed

 

 

 

 

 

 

 

Content   ..  402  403  404  405   ..