TM-128 < DTC/CIRCUIT DIAGNOSIS > [CVT: RE0F08B] P0744 TORQUE CONVERTER Is the inspection result normal? YES >> INSPECTION END NO >> Lock-up select solenoid valve is malfunctioning. Replace transaxle assembly. Refer to . CVT unit harness connector Ground Condition Resistance (Approx.) Connector Terminal F24 13 CVT fluid temperature: 20 ° C (68 ° F) 12.3 – 13.5 Ω CVT fluid temperature: 50 ° C (122 ° F) 13.7 – 15.1 Ω CVT fluid temperature: 80 ° C (176 ° F) 15.1 – 16.7 Ω |