EC-138

< DTC/CIRCUIT DIAGNOSIS >

[MR18DE]

P0031, P0032 A/F SENSOR 1 HEATER

P0031, P0032 A/F SENSOR 1 HEATER

Description

INFOID:0000000009947252

SYSTEM DESCRIPTION

The ECM performs ON/OFF duty control of the A/F sensor 1 heater corresponding to the engine operating
condition to keep the temperature of A/F sensor 1 element at the specified range.

DTC Logic

INFOID:0000000009947253

DTC DETECTION LOGIC

DTC CONFIRMATION PROCEDURE

1.

PRECONDITIONING

If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
TESTING CONDITION:
Before performing the following procedure, confirm that battery voltage is more than between 11 V at
idle.

>> GO TO 2.

2.

PERFORM DTC CONFIRMATION PROCEDURE

1.

Start engine and let it idle for at least 10 seconds.

2.

Check 1st trip DTC.

Is 1st trip DTC detected?

YES

>> Go to 

EC-138, "Diagnosis Procedure"

.

NO

>> INSPECTION END

Diagnosis Procedure

INFOID:0000000009947254

1.

CHECK GROUND CONNECTION

1.

Turn ignition switch OFF.

2.

Check ground connection E38. Refer to Ground Inspection in 

GI-43, "Circuit Inspection"

.

Is the inspection result normal?

YES

>> GO TO 2.

NO

>> Repair or replace ground connection.

2.

CHECK AIR FUEL RATIO (A/F) SENSOR 1 POWER SUPPLY CIRCUIT

1.

Disconnect air fuel ratio (A/F) sensor 1 harness connector.

2.

Turn ignition switch ON.

Sensor

Input signal to ECM

ECM function

Actuator

Camshaft position sensor (PHASE)
Crankshaft position sensor (POS)

Engine speed

Air fuel ratio (A/F) sensor 1 
heater control

Air fuel ratio (A/F) sensor 1 
heater

Mass air flow sensor

Amount of intake air

 DTC No.

Trouble diagnosis name

DTC detecting condition

Possible cause

P0031

Air fuel ratio (A/F) sensor 1 
heater control circuit low

The current amperage in the A/F sensor 1 heater 
circuit is out of the normal range.
(An excessively low voltage signal is sent to ECM 
through the A/F sensor 1 heater.)

• Harness or connectors

(The A/F sensor 1 heater circuit is 
open or shorted.)

• A/F sensor 1 heater

P0032

Air fuel ratio (A/F) sensor 1 
heater control circuit high

The current amperage in the A/F sensor 1 heater 
circuit is out of the normal range.
(An excessively high voltage signal is sent to ECM 
through the A/F sensor 1 heater.)

• Harness or connectors

(The A/F sensor 1 heater circuit is 
shorted.)

• A/F sensor 1 heater

P0031, P0032 A/F SENSOR 1 HEATER

EC-139

< DTC/CIRCUIT DIAGNOSIS >

[MR18DE]

C

D

E

F

G

H

I

J

K

L

M

A

EC

N

P

O

3.

Check the voltage between A/F sensor 1 harness connector and ground.

Is the inspection result normal?

YES

>> GO TO 4.

NO

>> GO TO 3.

3.

DETECT MALFUNCTIONING PART

Check the following.
• Harness connectors E8, F1
• IPDM E/R harness connector E15
• 15 A fuse (No. 61)
• Harness for open or short between A/F sensor 1 and fuse

>> Repair or replace harness or connectors.

4.

CHECK A/F SENSOR 1 HEATER OUTPUT SIGNAL CIRCUIT

1.

Turn ignition switch OFF.

2.

Disconnect ECM harness connector.

3.

Check the continuity between A/F sensor 1 harness connector and ECM harness connector.

4.

Also check harness for short to ground and short to power.

Is the inspection result normal?

YES

>> GO TO 5.

NO

>> Repair open circuit, short to ground or short to power in harness or connectors.

5.

CHECK A/F SENSOR 1 HEATER

Refer to 

EC-140, "Component Inspection"

.

Is the inspection result normal?

YES

>> GO TO 7.

NO

>> GO TO 6.

6.

REPLACE AIR FUEL RATIO (A/F) SENSOR 1

Replace malfunctioning air fuel ratio (A/F) sensor 1. Refer to 

EM-29, "Exploded View"

.

CAUTION:

• Discard any A/F sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a

hard surface such as a concrete floor; use a new one.

• Before installing new A/F sensor, clean exhaust system threads using Oxygen Sensor Thread

Cleaner [commercial service tool (J-43897-18 or J-43897-12)] and approved Anti-seize Lubricant
(commercial service tool).

>> INSPECTION END

7.

CHECK INTERMITTENT INCIDENT

Perfor

GI-40, "Intermittent Incident"

.

>> Repair or replace.

A/F sensor 1

Ground

Voltage

Connector

Terminal

F50

4

Ground

Battery voltage

A/F sensor 1

ECM

Continuity

Connector

Terminal

Connector

Terminal

F50

3

F7

8

Existed

EC-140

< DTC/CIRCUIT DIAGNOSIS >

[MR18DE]

P0031, P0032 A/F SENSOR 1 HEATER

Component Inspection

INFOID:0000000009947255

1.

CHECK AIR FUEL RATIO (A/F) SENSOR 1

1.

Turn ignition switch OFF.

2.

Disconnect A/F sensor 1 harness connector.

3.

Check resistance between A/F sensor 1 terminals as per the following.

Is the inspection result normal?

YES

>> INSPECTION END

NO

>> GO TO 2.

2.

REPLACE AIR FUEL RATIO (A/F) SENSOR 1

Replace air fuel ratio (A/F) sensor 1. Refer to 

EM-29, "Exploded View"

.

CAUTION:

• Discard any sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a hard

surface such as a concrete floor; use a new one.

• Before installing new sensor, clean exhaust system threads using Oxygen Sensor Thread Cleaner

[commercial service tool (J-43897-18 or J43897-12)] and approved Anti-seize Lubricant (commercial
service tool).

>> INSPECTION END

Terminals

Resistance

3 and 4

1.8 - 2.44 

 [at 20

°

C (68

°

F)]

3 and 1, 2

 

(Continuity should not exist)

4 and 1, 2

P0037, P0038 HO2S2 HEATER

EC-141

< DTC/CIRCUIT DIAGNOSIS >

[MR18DE]

C

D

E

F

G

H

I

J

K

L

M

A

EC

N

P

O

P0037, P0038 HO2S2 HEATER

Description

INFOID:0000000009947256

SYSTEM DESCRIPTION

The ECM performs ON/OFF control of the heated oxygen sensor 2 heater corresponding to the engine speed,
amount of intake air and engine coolant temperature. 

OPERATION

DTC Logic

INFOID:0000000009947257

DTC DETECTION LOGIC

DTC CONFIRMATION PROCEDURE

1.

PRECONDITIONING

If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
TESTING CONDITION:
Before performing the following procedure, confirm that battery voltage is more than 11 V at idle.

>> GO TO 2.

2.

PERFORM DTC CONFIRMATION PROCEDURE

With CONSULT

1.

Turn ignition switch ON and select “DATA MONITOR” mode with CONSULT.

2.

Start engine and warm it up to normal operating temperature.

3.

Turn ignition switch OFF and wait at least 10 seconds.

4.

Start engine and keep the engine speed between 3,500 and 4,000 rpm for at least 1 minute under no load.

5.

Let engine idle for 1 minute.

6.

Check 1st trip DTC.

 With GST

Follow the procedure “With CONSULT” above.
Is 1st trip DTC detected?

Sensor

Input signal to ECM

ECM function

Actuator

Camshaft position sensor (PHASE)
Crankshaft position sensor (POS)

Engine speed

Heated oxygen sensor 2 
heater control

Heated oxygen sensor 2 heater

Engine coolant temperature sensor

Engine coolant temperature

Mass air flow sensor

Amount of intake air

Engine speed

Heated oxygen sensor 2 heater

Above 3,600 rpm

OFF

Below 3,600 rpm after the following conditions are met.
• Engine: After warming up
• Keeping the engine speed between 3,500 and 4,000 rpm for 1 

minute and at idle for 1 minute under no load

ON

DTC No.

Trouble diagnosis name

DTC detecting condition

Possible cause

P0037

Heated oxygen sensor 2 
heater control circuit low

The current amperage in the heated oxygen sensor 
2 heater circuit is out of the normal range.
(An excessively low voltage signal is sent to ECM 
through the heated oxygen sensor 2 heater.)

• Harness or connectors

(The heated oxygen sensor 2 heater 
circuit is open or shorted.)

• Heated oxygen sensor 2 heater

P0038

Heated oxygen sensor 2 
heater control circuit high

The current amperage in the heated oxygen sensor 
2 heater circuit is out of the normal range.
(An excessively high voltage signal is sent to ECM 
through the heated oxygen sensor 2 heater.)

• Harness or connectors

(The heated oxygen sensor 2 heater 
circuit is shorted.)

• Heated oxygen sensor 2 heater

 

 

 

 

 

 

 