MWI THE DOOR OPEN WARNING CONTINUES DISPLAYING, OR DOES NOT DIS- PLAY MWI-79 < SYMPTOM DIAGNOSIS > C D E F G H I J K L M B A O P THE DOOR OPEN WARNING CONTINUES DISPLAYING, OR DOES NOT Description INFOID:0000000011279839 • The door open warning is displayed even though all of the doors are closed. • The door open warning is not displayed even though a door is ajar. Diagnosis Procedure INFOID:0000000011279840 1. CHECK BCM INPUT SIGNAL Check the BCM input signal. Refer to DLK-156, "Component Function Check" (with Intelligent Key system) or DLK-330, "Component Function Check" (without Intelligent Key system). Is the inspection result normal? YES >> GO TO 2. NO >> GO TO 3. 2. CHECK COMBINATION METER INPUT SIGNAL 1. Select “METER/M&A” using CONSULT. 2. Select “DOOR W/L” in “Data Monitor”. 3. Check the “DOOR W/L” status according to the following conditions: Is the inspection result normal? YES >> Replace combination meter. Refer to MWI-84, "Removal and Installation" NO >> Replace BCM. Refer to BCS-75, "Removal and Installation" (with Intelligent Key system) or 135, "Removal and Installation" (without Intelligent Key system). 3. CHECK DOOR SWITCH SIGNAL CIRCUIT Check the door switch signal circuit. Refer to DLK-156, "Diagnosis Procedure" (with Intelligent Key system) or DLK-330, "Diagnosis Procedure" (without Intelligent Key system). Is the inspection result normal? YES >> GO TO 4. NO >> Repair or replace harness or connector. 4. CHECK DOOR SWITCH Check the door switch. Refer to DLK-157, "Component Inspection" (with Intelligent Key system) or (without Intelligent Key system). Is the inspection result normal? YES >> Replace combination meter. Refer to MWI-84, "Removal and Installation" NO >> Replace applicable door switch. Refer to DLK-276, "Removal and Installation" (with Intelligent Key system) or DLK-396, "Removal and Installation" (without Intelligent Key system). Monitor item Condition Status DOOR W/L Door open On Door closed Off |