MWI

THE DOOR OPEN WARNING CONTINUES DISPLAYING, OR DOES NOT DIS-

PLAY

MWI-79

< SYMPTOM DIAGNOSIS >

C

D

E

F

G

H

I

J

K

L

M

B

A

O

P

THE DOOR OPEN WARNING CONTINUES DISPLAYING, OR DOES NOT
DISPLAY

Description

INFOID:0000000011279839

• The door open warning is displayed even though all of the doors are closed.

• The door open warning is not displayed even though a door is ajar.

Diagnosis Procedure

INFOID:0000000011279840

1.

CHECK BCM INPUT SIGNAL

Check the BCM input signal. Refer to 

DLK-156, "Component Function Check"

 (with Intelligent Key system) or

DLK-330, "Component Function Check"

 (without Intelligent Key system).

Is the inspection result normal?

YES

>> GO TO 2.

NO

>> GO TO 3.

2.

CHECK COMBINATION METER INPUT SIGNAL

1. Select “METER/M&A” using CONSULT.

2. Select “DOOR W/L” in “Data Monitor”.

3. Check the “DOOR W/L” status according to the following conditions:

Is the inspection result normal?

YES

>> Replace combination meter. Refer to 

MWI-84, "Removal and Installation"

.

NO

>> Replace BCM. Refer to 

BCS-75, "Removal and Installation"

 (with Intelligent Key system) or 

BCS-

135, "Removal and Installation"

 (without Intelligent Key system).

3.

CHECK DOOR SWITCH SIGNAL CIRCUIT

Check the door switch signal circuit. Refer to 

DLK-156, "Diagnosis Procedure"

 (with Intelligent Key system) or

DLK-330, "Diagnosis Procedure"

 (without Intelligent Key system).

Is the inspection result normal?

YES

>> GO TO 4.

NO

>> Repair or replace harness or connector.

4.

CHECK DOOR SWITCH

Check the door switch. Refer to 

DLK-157, "Component Inspection"

 (with Intelligent Key system) or 

DLK-331,

"Component Inspection"

 (without Intelligent Key system).

Is the inspection result normal?

YES

>> Replace combination meter. Refer to 

MWI-84, "Removal and Installation"

.

NO

>> Replace applicable door switch. Refer to 

DLK-276, "Removal and Installation"

 (with Intelligent Key

system) or 

DLK-396, "Removal and Installation"

 (without Intelligent Key system).

Monitor item

Condition

Status

DOOR W/L

Door open

On

Door closed

Off

MWI-80

< SYMPTOM DIAGNOSIS >

THE LIFTGATE OPEN WARNING CONTINUES DISPLAYING, OR DOES NOT 

DISPLAY

THE LIFTGATE OPEN WARNING CONTINUES DISPLAYING, OR DOES
NOT DISPLAY

Description

INFOID:0000000011279841

• The liftgate open warning is displayed continuously even though the liftgate is closed.

• The liftgate open warning is not displayed even though the liftgate is open.

Diagnosis Procedure

INFOID:0000000011279842

1.

CHECK BCM INPUT SIGNAL

Check the BCM input signal. Refer to 

DLK-156, "Component Function Check"

 (with Intelligent Key system) or

DLK-330, "Component Function Check"

 (without Intelligent Key system).

Is the inspection result normal?

YES

>> GO TO 2.

NO

>> GO TO 3.

2.

CHECK COMBINATION METER INPUT SIGNAL

1. Select “METER/M&A” using CONSULT.

2. Select “DOOR W/L” in “Data Monitor”.

3. Check the “DOOR W/L” status according to the following conditions:

Is the inspection result normal?

YES

>> Replace combination meter. Refer to 

MWI-84, "Removal and Installation"

.

NO

>> Replace BCM. Refer to 

BCS-75, "Removal and Installation"

 (with Intelligent Key system) or 

BCS-

135, "Removal and Installation"

 (without Intelligent Key system).

3.

CHECK BACK DOOR SWITCH SIGNAL CIRCUIT

Check the back door switch signal circuit. Refer to 

DLK-158, "Diagnosis Procedure (With Automatic Back

Door)"

 or 

DLK-159, "Diagnosis Procedure (Without Automatic Back Door)"

.

Is the inspection result normal?

YES

>> GO TO 4.

NO

>> Repair or replace harness or connector.

4.

CHECK BACK DOOR SWITCH

Check the back door switch. Refer to 

DLK-160, "Component Inspection (With Automatic Back Door)"

 or 

DLK-

161, "Component Inspection (Without Automatic Back Door)"

.

Is the inspection result normal?

YES

>> Replace combination meter. Refer to 

MWI-84, "Removal and Installation"

.

NO

>> Replace back door switch. Refer to 

DLK-270, "DOOR LOCK : Removal and Installation"

.

Monitor item

Condition

Status

DOOR W/L

Back door open

On

Back door closed

Off

MWI

THE METER CONTROL SWITCH IS INOPERATIVE

MWI-81

< SYMPTOM DIAGNOSIS >

C

D

E

F

G

H

I

J

K

L

M

B

A

O

P

THE METER CONTROL SWITCH IS INOPERATIVE

Description

INFOID:0000000011279843

The meter control switches are inoperative when pressed.

Diagnosis Procedure

INFOID:0000000011279844

1.

CHECK METER CONTROL SWITCH SIGNAL 

Check the meter control switch signal. Refer to 

MWI-69, "Diagnosis Procedure"

Is the inspection result normal?

YES

>> GO TO 2.

NO

>> Repair or replace harness or connector.

2.

CHECK METER CONTROL SWITCH

Check the meter control switch. Refer to 

MWI-70, "Component Inspection"

Is the inspection result normal?

YES

>> Replace combination meter. Refer to 

MWI-84, "Removal and Installation"

.

NO

>> Replace meter control switch. Refer to 

MWI-85, "Removal and Installation"

.

MWI-82

< SYMPTOM DIAGNOSIS >

THE STEERING SWITCHES ARE INOPERATIVE

THE STEERING SWITCHES ARE INOPERATIVE

Description

INFOID:0000000011279845

One or more of the steering switches to control the information display are inoperative.

Diagnosis Procedure

INFOID:0000000011279846

1.

CHECK STEERING SWITCH CIRCUIT

Check steering switch circuit. Refer to 

MWI-71, "Diagnosis Procedure"

.

Is the inspection result normal?

YES

>> GO TO 2.

NO

>> Repair or replace harness or connector.

2.

CHECK STEERING SWITCH RESISTANCE

Check steering switch resistance. Refer to 

MWI-71, "Component Inspection"

.

Is the inspection result normal?

YES

>> GO TO 3.

NO

>> Replace steering switch. Refer to 

AV-68, "Removal and Installation"

.

3.

CHECK SPIRAL CABLE

Check spiral cable for continuity. Refer to 

MWI-71, "Component Inspection"

.

Is the inspection result normal?

YES

>> Replace combination meter. Refer to 

MWI-84, "Removal and Installation"

.

NO

>> Replace spiral cable. Refer to 

SR-15, "Removal and Installation"

.

 

 

 

 

 

 

 

Content   ..  931  932  933  934   ..