HAC-178 < SYMPTOM DIAGNOSIS > [MANUAL AIR CONDITIONING] INSUFFICIENT HEATING INSUFFICIENT HEATING Component Function Check INFOID:0000000011276715 SYMPTOM: Insufficient heating INSPECTION FLOW 1. CONFIRM SYMPTOM BY PERFORMING OPERATION CHECK - TEMPERATURE INCREASE 1. Turn temperature control dial clockwise to maximum heat. 2. Check for hot air at discharge air outlets. YES >> GO TO 3. NO >> GO TO 2. 2. CHECK FOR ANY SYMPTOMS Perform a complete operational check and check for any symptoms. Refer to Does another symptom exist? YES >> Refer to . NO >> System OK. 3. CHECK FOR SERVICE BULLETINS Check for any service bulletins. >> GO TO 4. 4. CHECK ENGINE COOLING SYSTEM 1. Check for proper engine coolant level. Refer to 2. Check hoses for leaks or kinks. 3. Check radiator cap. Refer to CO-12, "RADIATOR CAP : Inspection" 4. Check for air in cooling system. >> GO TO 5. 5. CHECK AIR MIX DOOR MOTOR OPERATION Check and verify air mix door mechanism for smooth operation. YES >> GO TO 6. NO >> Check the air mix door motor circuit. Refer to HAC-164, "Diagnosis Procedure" . 6. CHECK AIR DUCTS Check for disconnected or leaking air ducts. YES >> GO TO 7. NO >> Repair all disconnected or leaking air ducts. 7. CHECK HEATER HOSE TEMPERATURES 1. Start engine and warm it up to normal operating temperature. 2. Touch both the inlet and outlet heater hoses. The inlet hose should be hot and the outlet hose should be warm. Is the inspection result normal? YES >> GO TO 8. NO >> Both hoses warm: GO TO 9. 8. CHECK ENGINE COOLANT SYSTEM Check thermostat operation. Refer to Is the inspection result normal? |