Nissan Rogue. Manual - part 788

 

  Index      Nissan     Nissan Rogue (2015 year) - Service and Repair Manual

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  786  787  788  789   ..

 

 

Nissan Rogue. Manual - part 788

 

 

HAC-174

< DTC/CIRCUIT DIAGNOSIS >

[MANUAL AIR CONDITIONING]

ECV (ELECTRICAL CONTROL VALVE)

Is the inspection result normal?

YES

>> GO TO 6.

NO

>> Replace A/C compressor. Refer to 

HA-29, "Removal and Installation"

.

6.

CHECK INTERMITTENT INCIDENT

Refer to 

GI-44, "Intermittent Incident"

.

Is the inspection result normal?

YES

>> Replace front air control. Refer to 

HAC-182, "Removal and Installation"

.

NO

>> Repair or replace malfunctioning parts.

Component Inspection

INFOID:0000000011276712

1.

CHECK ECV (ELECTRICAL CONTROL VALVE)

1. Turn ignition switch OFF.

2. Disconnect A/C compressor connector.

3. Check continuity between A/C compressor connector F15 terminals.

Is the inspection result normal?

YES

>> Inspection End.

NO

>> Replace A/C compressor. Refer to 

HA-29, "Removal and Installation"

.

Terminals

Condition

Resistance (k

Ω)

(Approx.)

Temperature: 

°C (°F)

3

4

20 (68)

10.1 – 11.1

HEATER AND AIR CONDITIONING SYSTEM CONTROL SYMPTOMS

HAC-175

< SYMPTOM DIAGNOSIS >

[MANUAL AIR CONDITIONING]

C

D

E

F

G

H

J

K

L

M

A

B

HAC

N

O

P

SYMPTOM DIAGNOSIS

HEATER AND AIR CONDITIONING SYSTEM CONTROL SYMPTOMS

Symptom Table

INFOID:0000000011276713

SYMPTOM TABLE

Symptom

Reference Page

A/C system does not come on.

Go to Trouble Diagnosis Procedure for A/C System.

HAC-167, "FRONT 

A/C CONTROL : Di-

agnosis Procedure"

Air outlet does not change.

Go to Trouble Diagnosis Procedure for Mode Door Motor.

HAC-161, "Diagno-

sis Procedure"

Mode door motor does not operate normally.

Discharge air temperature does not change.

Go to Trouble Diagnosis Procedure for Air Mix Door Motor.

HAC-164, "Diagno-

sis Procedure"

Air mix door motor does not operate normal-
ly.

Intake door does not change.

Go to Trouble Diagnosis Procedure for Intake Door Motor.

HAC-158, "Diagno-

sis Procedure"

Intake door motor does not operate normally.

Blower motor operation is malfunctioning.

Go to Trouble Diagnosis Procedure for Blower Motor.

HAC-168, "Diagno-

sis Procedure"

Magnet clutch does not engage.

Go to Trouble Diagnosis Procedure for Magnet Clutch.

HAC-172, "Compo-

nent Function 

Check"

Insufficient cooling

Go to Trouble Diagnosis Procedure for Insufficient Cooling.

HAC-176, "Compo-

nent Function 

Check"

Insufficient heating

Go to Trouble Diagnosis Procedure for Insufficient Heating.

HAC-178, "Compo-

nent Function 

Check"

Noise

Go to Trouble Diagnosis Procedure for Noise.

HA-20, "Symptom 

Table"

HAC-176

< SYMPTOM DIAGNOSIS >

[MANUAL AIR CONDITIONING]

INSUFFICIENT COOLING

INSUFFICIENT COOLING

Component Function Check

INFOID:0000000011276714

SYMPTOM: Insufficient cooling

INSPECTION FLOW

1.

 CONFIRM SYMPTOM BY PERFORMING OPERATION CHECK - TEMPERATURE DECREASE

1. Press the A/C switch. 

2. Turn temperature control dial counterclockwise to maximum cold.

3. Check for cold air at discharge air outlets.
Can a symptom be duplicated?

YES

>> GO TO 3.

 NO

>> GO TO 2.

2.

 CHECK FOR ANY SYMPTOMS

Perform a complete operational check and check for any symptoms. Refer to 

HAC-149, "Work Procedure"

.

Does another symptom exist?

YES

>> Refer to 

HAC-175, "Symptom Table"

.

NO

>> System OK. 

3.

 CHECK FOR SERVICE BULLETINS

Check for any service bulletins.

>> GO TO 4.

4.

 CHECK DRIVE BELTS

Check A/C compressor belt tension. Refer to 

EM-15, "Checking"

.

Is the inspection result normal?

YES

>> GO TO 5.

 NO

>> Adjust or replace compressor belt. Refer to 

EM-15, "Tension Adjustment"

.

5.

 CHECK AIR MIX DOOR MOTOR OPERATION

Check and verify air mix door mechanism for smooth operation.
Does air mix door operate correctly?

YES

>> GO TO 6.

 NO

>> Check air mix door motor circuit. Refer to 

HAC-164, "Diagnosis Procedure"

.

6.

 CHECK COOLING FAN MOTOR OPERATION

Check and verify cooling fan motor for smooth operation.
Does cooling fan motor operation correctly?

YES

>> GO TO 7.

NO

>> Check cooling fan motor. Refer to 

EC-461, "Component Function Check"

.

7.

 CHECK RECOVERY/RECYCLING EQUIPMENT BEFORE USAGE

Check recovery/recycling equipment before connecting to vehicle. Verify there is no pressure in the recovery/

recycling equipment by checking the gauges. If pressure exists, recover refrigerant from equipment lines.

>> GO TO 8.

8.

 CHECK REFRIGERANT PURITY

1. Connect recovery/recycling equipment to vehicle.

2. Confirm refrigerant purity in supply tank using recovery/recycling and refrigerant identifier.
Is the inspection result normal?

YES

>> GO TO 9.

NO

>> Check contaminated refrigerant. Refer to 

HA-21, "Description"

.

INSUFFICIENT COOLING

HAC-177

< SYMPTOM DIAGNOSIS >

[MANUAL AIR CONDITIONING]

C

D

E

F

G

H

J

K

L

M

A

B

HAC

N

O

P

9.

 CHECK REFRIGERANT PRESSURE

Check refrigerant pressure with manifold gauge connected. Refer to 

HA-27, "Inspection"

.

Is the inspection result normal?

YES

>> Perform diagnostic work flow. Refer to 

HA-15, "Workflow"

.

NO

>> GO TO 10.

10.

 CHECK FOR EVAPORATOR FREEZE UP

Start engine and run A/C. Check for evaporator freeze up. 
Does evaporator freeze up?

YES

>> Perform diagnostic work flow. Refer 

HA-15, "Workflow"

.

NO

>> GO TO 11.

11.

 CHECK AIR DUCTS 

Check ducts for air leaks. 
Is the inspection result normal?

YES

>> System OK.

NO

>> Repair air leaks.

 

 

 

 

 

 

 

Content   ..  786  787  788  789   ..