B1231 DAYTIME RUNNING LIGHT RH POWER SUPPLY CIRCUIT EXL-97 < DTC/CIRCUIT DIAGNOSIS > [HALOGEN HEADLAMP] C D E F G H I J K M A B EXL N O P B1231 DAYTIME RUNNING LIGHT RH POWER SUPPLY CIRCUIT DTC Logic INFOID:0000000011280748 DTC DETECTION LOGIC DTC CONFIRMATION PROCEDURE 1. CHECK SELF DIAGNOSTIC RESULT With CONSULT. 1. Turn ignition switch ON. 2. Perform “Self Diagnostic Result”. YES >> Proceed to diagnosis procedure. Refer to NO >> Inspection End. Diagnosis Procedure INFOID:0000000011280749 1. CHECK FRONT COMBINATION LAMP SHORT CIRCUIT TO GROUND 1. Disconnect front combination lamp connector and IPDM E/R connector. 2. Check continuity between IPDM E/R harness connector and ground. Is the inspection result normal? YES >> GO TO 2. NO >> Repair or replace harness. 2. CHECK FRONT COMBINATION LAMP SHORT CIRCUIT TO GROUND 1. Reconnect IPDM E/R connector. 2. Check continuity between front combination lamp harness connector and ground. Is the inspection result normal? YES >> Refer to GI-44, "Intermittent Incident" . NO >> Replace IPDM E/R. Refer to PCS-40, "Removal and Installation" . DTC Display Item Malfunction detected condition Possible causes B1231 DTRL RH PWR SPLY CIRC When a short circuit to ground in the daytime running • IPDM E/R IPDM E/R Ground Continuity Connector Terminal E218 58 No Front combination lamp Ground Continuity Connector Terminal RH E234 10 No |