WCS POWER SUPPLY AND GROUND CIRCUIT WCS-41 < DTC/CIRCUIT DIAGNOSIS > C D E F G H I J K L M B A O P Is the inspection result normal? YES >> GO TO 3. NO >> Repair or replace harness or connectors. 3. CHECK GROUND CIRCUIT Check continuity between BCM connector M20 and ground. Is the inspection result normal? YES >> Inspection End. NO >> Repair or replace harness or connectors. BCM Ground Voltage (Approx.) Connector Terminal M20 161 — Battery voltage BCM Ground Continuity Connector Terminal M20 170 — Yes 171 |