EVC-356 < DTC/CIRCUIT DIAGNOSIS > P31E8 WATER PUMP NO >> GO TO 4. 4. CHECK WATER PUMP FEEDBACK DUTY-3 With CONSULT 1. On the CONSULT screen, select “EV/HEV” >> “DATA MONITOR” >> “W/P 1 CRNT SPD DUTY” and “WATER PUMP 1 TRG DUTY”. 2. Check that “W/P 1 CRNT SPD DUTY” and “WATER PUMP 1 TRG DUTY” agree with the values listed below. Are the above values satisfied? YES >> GO TO 5. NO >> Check intermittent incident. Refer to GI-53, "Intermittent Incident" . 5. CHECK WATER PUMP SIGNAL CIRCUIT 1. Turn power switch OFF. 2. Disconnect electric water pump harness connector and VCM harness connector. 3. Check the continuity between electric water pump harness connector and VCM harness connector. 4. Also check harness for short to ground and short to power. YES >> GO TO 6. NO >> Repair or replace error-detected parts. 6. CHECK FUSE 1. Turn power switch OFF. 2. Pull out #71 fuse. 3. Make sure that the fuse is not fusing. YES >> GO TO 7. NO >> Replace the fuse after repairing the applicable circuit. 7. CHECK WATER PUMP INPUT POWER VOLTAGE 1. Insert the fuse which pulled out. 2. Disconnect water pump harness connector. 3. Turn power switch ON. 4. Check the voltage between water pump harness connector and ground. Is the inspection result normal? YES >> Replace electric water pump. Refer to HCO-25, "Removal and Installation" . NO >> GO TO 8. 8. CHECK WATER PUMP INPUT POWER CIRCUIT-1 1. Turn power switch OFF. W/P 1 CRNT SPD DUTY 17 – 82% WATER PUMP 1 TRG DUTY 20 – 80% Electric water pump VCM Continuity Connector Terminals Connector Terminals E67 3 E61 20 Existed 4 19 + − Voltage Electric water pump Connector Terminal E67 1 Ground 12V battery volt- age |