BACK DOOR OPENER SWITCH DLK-83 < DTC/CIRCUIT DIAGNOSIS > C D E F G H I J L M A B DLK N O P Is the inspection result normal? YES >> Replace BCM. Refer to BCS-72, "Removal and Installation" NO >> Repair or replace harness. 3. CHECK BACK DOOR OPENER SWITCH GROUND CIRCUIT Check continuity between back door opener switch assembly harness connector and ground. Is the inspection result normal? YES >> GO TO 4. NO >> Repair or replace harness. 4. CHECK BACK DOOR OPENER SWITCH DLK-83, "Component Inspection" Is the inspection result normal? YES >> GO TO 5. NO >> Replace back door opener switch assembly. Refer to DLK-212, "Removal and Installation" . 5. CHECK INTERMITTENT INCIDENT GI-53, "Intermittent Incident" . >> Inspection End. Component Inspection INFOID:0000000010119757 1. CHECK BACK DOOR OPENER SWITCH 1. Turn power switch OFF. 2. Disconnect back door opener switch assembly connector. 3. Check continuity between back door opener switch assembly terminals. Is the inspection result normal? YES >> Inspection End. NO >> Replace back door opener switch assembly. Refer to DLK-212, "Removal and Installation" . BCM Ground Continuity Connector Terminal M24 30 No Back door opener switch assembly Ground Continuity Connector Terminal D563 2 Yes Back door opener switch assembly Condition Continuity Terminal 1 2 Back door opener Pressed Yes Released No |