содержание .. 266 267 268 269 ..
SE-14 < DTC/CIRCUIT DIAGNOSIS > POWER SUPPLY AND GROUND CIRCUIT DTC/CIRCUIT DIAGNOSIS POWER SUPPLY AND GROUND CIRCUIT HEATED SEAT CONTROL UNIT HEATED SEAT CONTROL UNIT : Diagnosis Procedure INFOID:0000000009162908 1. CHECK FUSE Check that the following fuse is not fusing. Is the inspection result normal? YES >> GO TO 2. NO >> Replace the blown fuse after repairing the affected circuit if a fuse is blown. 2. CHECK POWER SUPPLY 1. Turn ignition switch OFF. 2. Disconnect heated seat control unit connector. 3. Turn ignition switch ON. 4. Check voltage between heated seat control unit harness connector and ground. Is the inspection result normal? YES >> GO TO 4. NO >> GO TO 3. 3. CHECK POWER SUPPLY CIRCUIT 1. Turn ignition switch OFF. 2. Disconnect heated seat relay connector. 3. Check continuity between heated seat control unit harness connector and heated seat relay terminal con- 4. Check continuity between heated seat control unit harness connector and ground. Is the inspection result normal? YES >> Check heated seat relay. Refer to SE-20, "Component Function Check" NO >> Repair or replace harness. 4. CHECK GROUND CIRCUIT 1. Turn ignition switch OFF. 2. Check continuity between heated seat control unit harness connector and ground. Signal name Fuse No. Battery power supply 35 (15 A) (+) ( − ) Voltage (V) (Approx.) Heated seat control unit Connector Terminal B519 18 Ground Battery voltage Heated seat control unit Heated seat relay Continuity Connector Terminal Connector Terminal B519 18 M70 3 Existed Heated seat control unit Ground Continuity Connector Terminal B519 18 Not existed |