содержание .. 1209 1210 1211 1212 ..
SE-32 < DTC/CIRCUIT DIAGNOSIS > RETURN COMPLETE LIMIT SWITCH Is the inspection result normal? YES >> GO TO 5. NO >> Replace return complete limit switch (RH) [reclining device assembly (RH)]. Refer to . 5. CHECK INTERMITTENT INCIDENT GI-39, "Intermittent Incident" >> INSPECTION END RH : Component Inspection INFOID:0000000005518178 COMPONENT INSPECTION 1. CHECK RETURN COMPLETE LIMIT SWITCH (RH) 1. Turn ignition switch OFF. 2. Disconnect return complete limit switch (RH) connector. 3. Check return complete limit switch (RH) terminals. Is the inspection result normal? YES >> Return complete limit switch (RH) is OK. NO >> Replace return complete limit switch (RH) [reclining device assembly (RH)]. Refer to . Return complete limit switch (RH) connector Terminal Condition Continuity B496 1 2 Return complete limit switch (RH) is pressed Existed Return complete limit switch (RH) is released Not existed |