DTC P0453 EVAP CONTROL SYSTEM PRESSURE SENSOR EC-383 C D E F G H I J K L M A EC Revision; 2004 April 2003 Murano 3. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT 1. Turn ignition switch “ON”. 2. Check voltage between EVAP control system pressure sensor OK or NG OK >> GO TO 5. NG >> GO TO 4. 4. DETECT MALFUNCTIONING PART Check the following. ● Harness connectors B2, M9 ● Harness connectors M82, F102 ● Harness for open or short between EVAP control system pressure sensor and ECM >> Repair open circuit or short to ground or short to power in harness or connectors. 5. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR GROUND CIRCUIT FOR OPEN AND SHORT 1. Turn ignition switch “OFF”. 2. Check harness continuity between EVAP control system pressure sensor terminal 1 and engine ground. 3. Also check harness for short to ground and short to power. OK or NG OK >> GO TO 7. NG >> GO TO 6. 6. DETECT MALFUNCTIONING PART Check the following. ● Harness connectors B2, M9 ● Harness connectors M82, F102 ● Joint connector-3 ● Harness for open or short between EVAP control system pressure sensor and ECM >> Repair open circuit or short to ground or short to power in harness or connectors. Voltage: Approximately 5V PBIB0138E Continuity should exist. |