CLOSE SWITCH DLK-147 < DTC/CIRCUIT DIAGNOSIS > [WITH INTELLIGENT KEY SYSTEM] C D E F G H I J L M A B DLK N O P CLOSE SWITCH Description INFOID:0000000009719081 The close switch is integrated in the door lock assembly, and it detects the close condition of the back door Component Function Check INFOID:0000000009719082 1. CHECK FUNCTION Check close switch (“CLOSE SW”) in Data Monitor mode. Is the inspection result normal? YES >> Close switch is OK. NO >> Refer to DLK-147, "Diagnosis Procedure" Diagnosis Procedure INFOID:0000000009719083 1. CHECK AUTOMATIC BACK DOOR CONTROL UNIT OUTPUT SIGNAL 1. Turn ignition switch OFF. 2. Disconnect back door lock assembly connector. 3. Check voltage between back door lock assembly harness connector and ground. Is the inspection result normal? YES >> GO TO 3. NO >> GO TO 2. 2. CHECK CLOSE SWITCH CIRCUIT 1. Disconnect automatic back door control unit connector. 2. Check continuity between automatic back door control unit harness connector and back door lock assem- 3. Check continuity between automatic back door control unit harness connector and ground. Is the inspection result normal? YES >> Replace automatic back door control unit. Refer to DLK-368, "Removal and Installation" . NO >> Repair or replace harness. 3. CHECK CLOSE SWITCH GROUND CIRCUIT Check continuity between back door lock assembly harness connector and ground. Monitor item Condition Status CLOSE SW Back door lock Open/Half latch OFF Fully closed ON (+) (–) Voltage (V) (Approx.) Back door lock assembly Connector Terminal D179 5 Ground Battery voltage Automatic back door control unit Back door lock assembly Continuity Connector Terminal Connector Terminal B8 19 D179 5 Existed Automatic back door control unit Ground Continuity Connector Terminal B8 19 Not existed |