содержание .. 380 381 382 383 ..
AUTOMATIC BACK DOOR CLOSE SWITCH DLK-139 < DTC/CIRCUIT DIAGNOSIS > [WITH INTELLIGENT KEY SYSTEM] C D E F G H I J L M A B DLK N O P AUTOMATIC BACK DOOR CLOSE SWITCH Description INFOID:0000000009719065 Automatic back door system can be operated (only close operation) from back door area by automatic back Component Function Check INFOID:0000000009719066 1. CHECK FUNCTION Check automatic back door close switch (“BK DOOR CL SW”) in Data Monitor mode. Is the inspection result normal? YES >> Automatic back door close switch is OK. NO >> Refer to DLK-139, "Diagnosis Procedure" Diagnosis Procedure INFOID:0000000009719067 1. CHECK AUTOMATIC BACK DOOR CONTROL UNIT OUTPUT 1. Turn ignition switch OFF. 2. Disconnect automatic back door close switch connector. 3. Check voltage between automatic back door close switch harness connector and ground. Is the inspection result normal? YES >> GO TO 3. NO >> GO TO 2. 2. CHECK AUTOMATIC BACK DOOR CLOSE SWITCH CIRCUIT 1. Disconnect automatic back door close switch connector. 2. Check continuity between automatic back door control unit harness connector and automatic back door 3. Check continuity between automatic back door control unit harness connector and ground. Is the inspection result normal? YES >> Replace automatic back door control unit. Refer to DLK-368, "Removal and Installation" . NO >> Repair or replace harness. 3. CHECK AUTOMATIC BACK DOOR CLOSE SWITCH GROUND CIRCUIT Check continuity between automatic back door close switch harness connector and ground. Monitor item Condition Status BK DOOR CL SW Automatic back door close switch Pressed ON Released OFF (+) (–) Voltage (V) (Approx.) Automatic back door close switch Connector Terminal D178 1 Ground Battery voltage Automatic back door control unit Automatic back door close switch Continuity Connector Terminal Connector Terminal B8 4 D178 1 Existed Automatic back door control unit Ground Continuity Connector Terminal B8 4 Not existed |