содержание .. 298 299 300 301 ..
DAS-90 < SYMPTOM DIAGNOSIS > [LDW] LDW ON INDICATOR LAMP DOES NOT TURNED ON LDW ON INDICATOR LAMP DOES NOT TURNED ON Description INFOID:0000000009723287 The LDW ON indicator lamp in the combination meter does not turn ON when turning on the ignition switch Diagnosis Procedure INFOID:0000000009723288 1. CHECK COMBINATION METER Turn the ignition switch from OFF to ON to check that “LDW IND” included in “DATA MONITOR” in “METER/ YES >> Replace the combination meter. Refer to MWI-105, "Removal and Installation" NO >> GO TO 2. 2. CHECK SELF-DIAGNOSIS RESULTS OF COMBINATION METER 1. Perform “All DTC Reading” with CONSULT. 2. Check if the DTC is detected in self-diagnosis results of “METER/M&A” Refer to . Is any DTC detected? YES >> Repair or replace malfunctioning parts. NO >> GO TO 3. 3. CHECK SELF-DIAGNOSIS RESULTS OF CAMERA CONTROL UNIT Check if the DTC is detected in self-diagnosis results of “AVM” Refer to . Is any DTC detected? YES >> Repair or replace malfunctioning parts. NO >> Replace the camera control unit. Refer to DAS-94, "Removal and Installation" . |