Nissan X-Trail 32. Manual - part 2107

 

 

TM-386

< DTC/CIRCUIT DIAGNOSIS >

[CVT: RE0F10D]

P2815 SELECT SOLENOID

P2815 SELECT SOLENOID

DTC Description

INFOID:0000000010622573

DTC DETECTION LOGIC

POSSIBLE CAUSE

• Harness or connector (Select solenoid valve circuit open or shorted to power supply)
• Select solenoid valve

FAIL-SAFE

Selector shock is large

DTC CONFIRMATION PROCEDURE

1.

PREPARATION BEFORE WORK

If another "DTC CONFIRMATION PROCEDURE" occurs just before, turn ignition switch OFF and wait for at
least 10 seconds, then perform the next test.

>> GO TO 2.

2.

CHECK DTC DETECTION

1.

Start the engine.

2.

Maintain the following conditions. (Keep 5 seconds or more after the selector lever shifted.)

3.

Check the first trip DTC.

Is “P2815” detected?

YES

>> Go to 

TM-386, "Diagnosis Procedure"

.

NO-1

>> To check malfunction symptom before repair: Refer to 

GI-44, "Intermittent Incident"

.

NO-2

>> Confirmation after repair: INSPECTION END

Diagnosis Procedure

INFOID:0000000010622574

1.

CHECK CIRCUIT BETWEEN TCM AND CVT UNIT

1.

Turn ignition switch OFF.

2.

Disconnect TCM connector and CVT unit connector.

3.

Check continuity between TCM harness connector terminal and CVT unit harness connector terminal. 

Is the inspection result normal?

YES 

>> GO TO 2.

NO

>> Repair or replace damaged parts.

2.

CHECK SELECT SOLENOID VALVE CIRCUIT

Check continuity between CVT unit harness connector terminal and ground. 

DTC

CONSULT screen terms

(Trouble diagnosis content)

DTC detection condition

P2815

SELECT SOLENOID
(Select solenoid)

When all of the following conditions are satisfied and this state is main-
tained for 0.2 seconds:
• TCM power supply voltage: More than 11 V
• TCM judges that solenoid valve circuit is open. 
• P2814 is not detected. 

Selector lever

: N 

 D, N 

 R, P 

 R

TCM

CVT unit

Continuity

Connector

Terminal

Connector

Terminal

F23

37

F24

4

Existed

P2815 SELECT SOLENOID

TM-387

< DTC/CIRCUIT DIAGNOSIS >

[CVT: RE0F10D]

C

E

F

G

H

I

J

K

L

M

A

B

TM

N

O

P

Is the inspection result normal?

YES >> INSPECTION 

END

NO

>> There is malfunction of select solenoid valve. Replace transaxle assembly. Refer to 

TM-450,

"Removal and Installation"

.

CVT unit

Condition

Resistance

Connector

Terminal

F250

4

Ground

CVT fluid temperature: 20

°

C (68

°

F)

5.5 – 7.0 

CVT fluid temperature: 50

°

C (122

°

F)

6.0 – 8.0 

CVT fluid temperature: 80

°

C (176

°

F)

6.5 – 8.5 

TM-388

< DTC/CIRCUIT DIAGNOSIS >

[CVT: RE0F10D]

MAIN POWER SUPPLY AND GROUND CIRCUIT

MAIN POWER SUPPLY AND GROUND CIRCUIT

Diagnosis Procedure

INFOID:0000000010622575

1.

CHECK TCM POWER CIRCUIT (PART 1)

1.

Turn ignition switch OFF.

2.

Disconnect TCM connector.

3.

Check voltage between TCM harness connector terminals and ground.

Is the inspection result normal?

YES

>> GO TO 2.

NO

>> GO TO 4.

2.

CHECK TCM POWER CIRCUIT (PART 2)

Check voltage between TCM harness connector terminals and ground.

Is the inspection result normal?

YES

>> GO TO 3.

NO

>> GO TO 5.

3.

CHECK TCM GROUND CIRCUIT

Check continuity between TCM harness connector terminals and ground.

Is the inspection result normal?

YES

>> Check intermittent incident. Refer to 

GI-44, "Intermittent Incident"

.

NO

>> Repair or replace malfunctioning parts.

4.

DETECT MALFUNCTION ITEMS (PART 1)

Check the following items:
• Open circuit or short circuit in harness between battery positive terminal and TCM connector terminal 45,

and 46. Refer to 

PG-12, "Wiring Diagram - BATTERY POWER SUPPLY -"

.

• 10A fuse (No.49, located in the fuse and fusible link block). Refer to 

PG-86, "Fuse and Fusible Link Arrange-

ment"

.

Is the inspection result normal?

YES >> Check 

intermittent incident. Refer to 

GI-44, "Intermittent Incident"

.

NO

>> Repair or replace malfunctioning parts.

+

Voltage

TCM

Connector

Terminal

F23

45

Ground

10 – 16 V

46

+

Condition

Voltage

TCM

Connector

Terminal

F23

47

Ground

Ignition switch ON

10 – 16 V

Ignition switch OFF

Approx. 0 V

48

Ignition switch ON

10 – 16 V

Ignition switch OFF

Approx. 0 V

TCM

Continuity

Connector

Terminal

F23

41

Ground

Existed

42

MAIN POWER SUPPLY AND GROUND CIRCUIT

TM-389

< DTC/CIRCUIT DIAGNOSIS >

[CVT: RE0F10D]

C

E

F

G

H

I

J

K

L

M

A

B

TM

N

O

P

5.

CHECK CIRCUIT BETWEEN IPDM E/R AND TCM

1.

Turn ignition switch OFF.

2.

Disconnect IPDM E/R connector.

3.

Check continuity between IPDM E/R harness connector terminal and TCM harness connector terminals.

Is the check result normal?

YES

>> GO TO 6.

NO

>> Repair or replace malfunctioning parts.

6.

DETECT MALFUNCTIONING ITEMS (PART 2)

Check the following items:
• Open circuit or short circuit in harness between ignition switch and IPDM E/R. Refer to 

PG-52, "Wiring Dia-

gram - IGNITION POWER SUPPLY -"

.

• Short circuit in harness between IPDM E/R harness connector terminal 70 and TCM harness connector ter-

minals 47, and 48.

• 10A fuse (No.93, located in the IPDM E/R). Refer to 

PG-89, "Fuse, Connector and Terminal Arrangement"

.

• IPDM E/R

Is the check result normal?

YES

>> Check intermittent incident. Refer to 

GI-44, "Intermittent Incident"

.

NO

>> Repair or replace malfunctioning parts.

IPDM E/R

TCM

Continuity

Connector

Terminal

Connector

Terminal

F72

70

F23

47

Existed

48

 

 

 

 

 

 

 