содержание .. 1880 1881 1882 1883 ..
SECURITY INDICATOR LAMP SEC-295 < DTC/CIRCUIT DIAGNOSIS > [WITHOUT INTELLIGENT KEY SYSTEM] C D E F G H I J L M A B SEC N O P SECURITY INDICATOR LAMP Diagnosis Procedure INFOID:0000000010922310 1. CHECK FUSE 1. Turn power switch OFF. 2. Check that the following fuse in the fuse block (J/B) is not blown. Is the inspection result normal? YES >> GO TO 2. NO >> Replace the blown fuse after repairing the cause of blowing. 2. CHECK SECURITY INDICATOR LAMP POWER SUPPLY CIRCUIT 1. Disconnect combination meter connector. 2. Check voltage between combination meter harness connector and ground. Is the inspection result normal? YES >> GO TO 3. NO >> Repair or replace harness. 3. CHECK SECURITY INDICATOR LAMP SIGNAL 1. Connect combination meter connector. 2. Disconnect BCM connector. 3. Turn ignition switch ON. 4. Check voltage between BCM harness connector and ground. Is the inspection result normal? YES >> GO TO 4. NO >> GO TO 5. 4. REPLACE BCM BCS-121, "Removal and Installation" . >> INSPECTION END 5. CHECK SECURITY INDICATOR LAMP CIRCUIT 1. Turn ignition switch OFF. 2. Disconnect combination meter connector. 3. Check continuity between combination meter harness connector and BCM harness connector. 4. Check continuity between combination meter harness connector and ground. Signal name Fuse No. Battery power supply 13 (10 A) (+) (–) Voltage (V) (Approx.) Combination meter Connector Terminal M42 45 Ground Battery voltage (+) (–) Voltage BCM Connector Terminal M87 75 Ground 9 - 16 V Combination meter BCM Continuity Connector Terminal Connector Terminal M34 7 M87 75 Existed |