Nissan Qashqai J11. Manual - part 1745

 

  Index      Nissan     Nissan Qashqai J11 - Service and Repair Manual

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  1743  1744  1745  1746   ..

 

 

Nissan Qashqai J11. Manual - part 1745

 

 

EXL-282

< DTC/CIRCUIT DIAGNOSIS >

[HALOGEN HEADLAMP]

DAYTIME RUNNING LIGHT CIRCUIT

DAYTIME RUNNING LIGHT CIRCUIT

Component Function Check

INFOID:0000000010469982

1.

CHECK DAYTIME RUNNING LIGHT OPERATION

With CONSULT

1.

Select “DAYTIME RUNNING LIGHT” in “Active Test” mode of “IPDM E/R” using CONSULT.

2.

With operating the test items, check that the daytime running light is turned ON.

Is the inspection result normal?

YES

>> Daytime running light circuit is normal.

NO

>> Refer to 

EXL-282, "Diagnosis Procedure"

.

Diagnosis Procedure

INFOID:0000000010469983

1.

CHECK DAYTIME RUNNING LIGHT OUTPUT VOLTAGE

With CONSULT

1.

Turn ignition switch OFF.

2.

Disconnect front combination lamp connector.

3.

Turn ignition switch ON.

4.

Select “DAYTIME RUNNING LIGHT” in “Active Test” mode of “IPDM E/R” using CONSULT.

5.

With operating the test items, check voltage between IPDM E/R harness connector and ground.

Is the inspection result normal?

YES

>> GO TO 2.

NO

>> Replace IPDM E/R. Refer to 

PCS-67, "Removal and Installation"

.

2.

CHECK DAYTIME RUNNING LIGHT POWER SUPPLY CIRCUIT

1.

Turn ignition switch OFF.

2.

Disconnect IPDM E/R connector.

3.

Check continuity between IPDM E/R harness connector and front combination lamp harness connector.

Is the inspection result normal?

YES

>> GO TO 3.

NO

>> Repair or replace harness.

3.

CHECK DAYTIME RUNNING LIGHT GROUND CIRCUIT

Check continuity between front combination lamp harness connector and ground.

On

: Daytime running light ON

Off

: Daytime running light OFF

+

-

Test item

Voltage

IPDM E/R

Connector

Terminal

RH

E101

50

Ground

DAYTIME RUN-
NING LIGHT

On

9 – 16 V

Off

0 – 1 V

LH

E102

57

On

9 – 16 V

Off

0 – 1 V

IPDM E/R

Front combination lamp

Continuity

Connector

Terminal

Connector

Terminal

RH

E101

50

E92

2

Existed

LH

E102

57

E90

DAYTIME RUNNING LIGHT CIRCUIT

EXL-283

< DTC/CIRCUIT DIAGNOSIS >

[HALOGEN HEADLAMP]

C

D

E

F

G

H

I

J

K

M

A

B

EXL

N

O

P

Is the inspection result normal?

YES

>> Replace the corresponding front combination lamp. Refer to 

EXL-318, "Removal and Installation"

.

NO

>> Repair or replace harness.

Front combination lamp

Continuity

Connector

Terminal

RH

E92

1

Ground

Existed

LH

E90

EXL-284

< DTC/CIRCUIT DIAGNOSIS >

[HALOGEN HEADLAMP]

STOP LAMP CIRCUIT

STOP LAMP CIRCUIT

Component Function Check

INFOID:0000000010469984

1.

CHECK STOP LAMP OPERATION

1.

Turn ignition switch ON.

2.

With operating the brake pedal, check that the stop lamp and high-mounted stop lamp is turned ON.

Is the inspection result normal?

YES

>> Stop lamp circuit is normal.

NO

>> Refer to 

EXL-284, "Diagnosis Procedure"

.

Diagnosis Procedure

INFOID:0000000010469985

1.

CHECK SYMPTOM

Check symptom (A or B)

Which symptom is detected?

A

>> GO  TO  2.

B

>> GO  TO  7.

2.

CHECK FUSE

1.

Turn ignition switch OFF.

2.

Check that the following fuse is not fusing.

Is the inspection result normal?

YES

>> GO TO 3.

NO

>> Replace the blown fuse after repairing the affected circuit if a fuse is blown.

3.

CHECK BCM POWER SUPPLY (STOP LAMP)

1.

Disconnect BCM connector.

2.

Check voltage between BCM harness connector and ground.

Is the inspection result normal?

YES

>> GO TO 4.

NO

>> Repair or replace harness.

4.

CHECK STOP LAMP SWITCH POWER SUPPLY

1.

Disconnect stop lamp switch connector.

Depressed

: Stop lamp and high-mounted stop lamp 
ON

Fully re-
leased

: Stop lamp and high-mounted stop lamp 
OFF

Symptom

A

All of stop lamp and high-mounted stop lamp are not turned ON

B

Any of stop lamp and high-mounted stop lamp are not turned ON

Unit

Location

Fuse No.

Capacity

• BCM
• Stop lamp switch

Fuse block (J/B)

#24

10 A

+

-

Voltage

BCM

Connector

Terminal

M68

145

Ground

9 – 16 V

STOP LAMP CIRCUIT

EXL-285

< DTC/CIRCUIT DIAGNOSIS >

[HALOGEN HEADLAMP]

C

D

E

F

G

H

I

J

K

M

A

B

EXL

N

O

P

2.

Connect BCM connector.

3.

Turn ignition switch ON.

4.

Check voltage between stop lamp switch harness connector and ground.

Is the inspection result normal?

YES

>> GO TO 5.

NO

>> Repair or replace harness.

5.

CHECK STOP LAMP SWITCH SIGNAL CIRCUIT (OPEN)

1.

Turn ignition switch OFF.

2.

Disconnect BCM connector.

3.

Check continuity between BCM harness connector and stop lamp switch harness connector.

Is the inspection result normal?

YES

>> GO TO 6.

NO

>> Repair or replace harness.

6.

CHECK STOP LAMP SWITCH

Check stop lamp switch. Refer to 

EXL-287, "Component Inspection"

.

Is the inspection result normal?

YES

>> Replace BCM. Refer to 

BCS-132, "Removal and Installation"

.

NO

>> Replace stop lamp switch. Refer to 

BR-17, "Exploded View"

 (LHD models) or 

BR-61, "Exploded

View"

 (RHD models).

7.

CHECK STOP LAMP / HIGH-MOUNTED STOP LAMP OUTPUT VOLTAGE

With CONSULT

1.

Disconnect stop lamp / tail lamp (body side) connectors.

2.

Turn ignition switch ON.

3.

Select “HEAD LAMP” of “BCM” using CONSULT.

4.

Select “STOP LAMP 1”, “STOP LAMP 2” or “STOP LAMP 3” in “Active Test” mode.

5.

With operating the test items, check voltage between BCM harness connector and ground.

Stop lamp RH

Stop lamp LH

+

-

Voltage

Stop lamp switch

Connector

Terminal

M97

1

Ground

9 – 16 V

BCM

Stop lamp switch

Continuity

Connector

Terminal

Connector

Terminal

E60

157

E50

2

Existed

+

-

Test  item

Voltage

(Approx.)

BCM

Connector

Terminal

B3

134

Ground

STOP LAMP 1

On

9 – 16 V

Off

0 V

+

-

Test  item

Voltage

(Approx.)

BCM

Connector

Terminal

B3

129

Ground

STOP LAMP 2

On

9 – 16 V

Off

0 V

 

 

 

 

 

 

 

Content   ..  1743  1744  1745  1746   ..