Nissan Juke F15. Manual - part 545

 

  Index      Nissan     Nissan Juke F15 (2015 year) - Service and Repair Manual

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  543  544  545  546   ..

 

 

Nissan Juke F15. Manual - part 545

 

 

P044A, P044E EGR VOLUME CONTROL VALVE POSITION SENSOR

EC-993

< DTC/CIRCUIT DIAGNOSIS >

[MR EXCEPT FOR NISMO RS MODELS]

C

D

E

F

G

H

I

J

K

L

M

A

EC

N

P

O

P044A, P044E EGR VOLUME CONTROL VALVE POSITION SENSOR

DTC Logic

INFOID:0000000012198485

DTC DETECTION LOGIC

NOTE:

If DTC P044A, or P044E is displayed with DTC P0643, first perform trouble diagnosis for DTC P0643. Refer to

EC-1060, "DTC Logic"

.

DTC CONFIRMATION PROCEDURE

1.

PRECONDITIONING

If DTC Confirmation Procedure has been previously conducted, always perform the following procedure

before conducting the next test.

1. Turn ignition switch OFF and wait at least 10 seconds.

2. Turn ignition switch ON.

3. Turn ignition switch OFF and wait at least 10 seconds.

>> GO TO 2.

2.

PERFORM DTC CONFIRMATION PROCEDURE

1. Turn ignition switch ON and wait at least 5 seconds.

2. Check 1st trip DTC.
Is 1st trip DTC detected?

YES

>> Proceed to 

EC-993, "Diagnosis Procedure"

.

NO

>> INSPECTION END

Diagnosis Procedure

INFOID:0000000012198486

1.

CHECK EGR VOLUME CONTROL VALVE POSITION SENSOR POWER SUPPLY CIRCUIT

1. Turn ignition switch OFF.

2. Disconnect EGR volume control valve harness connector.

3. Turn ignition switch ON.

4. Check voltage between EGR volume control valve harness connector and ground.

Is the inspection result normal?

YES

>> GO TO 2.

NO

>> Perform the trouble diagnosis for power supply circuit.

2.

CHECK EGR VOLUME CONTROL VALVE POSITION SENSOR GROUND CIRCUIT

1. Turn ignition switch OFF.

2. Disconnect ECM harness connector.

3. Check harness continuity between EGR volume control valve harness connector and ECM harness con-

nector.

DTC No.

Trouble diagnosis name

(Trouble diagnosis content)

DTC detecting condition

Possible cause

P044A

EGR SENSOR C
(EGR sensor C circuit low)

ECM detects that a voltage signal from EGR 
volume control valve position sensor is less 
than 4.81 V for 5 consecutive seconds.

• Harness or connectors

(EGR volume control valve position 
sensor circuit is open or shorted.)

• EGR volume control valve

P044E

EGR SENSOR C
(EGR sensor C circuit high)

ECM detects that a voltage signal from EGR 
volume control valve position sensor is less 
than 0.275 V for 5 consecutive seconds.

+

Voltage

(Approx.)

EGR volume control valve

Connector

Terminal

F74

3

Ground

5 V

EC-994

< DTC/CIRCUIT DIAGNOSIS >

[MR EXCEPT FOR NISMO RS MODELS]

P044A, P044E EGR VOLUME CONTROL VALVE POSITION SENSOR

4. Also check harness for short to ground and short to power.
Is the inspection result normal?

YES

>> GO TO 3.

NO

>> Repair or replace error-detected parts.

3.

CHECK EGR VOLUME CONTROL VALVE POSITION SENSOR INPUT SIGNAL CIRCUIT

1. Check harness continuity between EGR volume control valve harness connector and ECM harness con-

nector.

2. Also check harness for short to ground and short to power.
Is the inspection result normal?

YES

>> GO TO 4.

NO

>> Repair or replace error-detected parts.

4.

CHECK EGR VOLUME CONTROL VALVE

Check the EGR volume control valve. Refer to 

EC-961, "Component Inspection (EGR Volume Control Valve)"

.

Is the inspection result normal?

YES

>> Check intermittent incident. Refer to 

GI-45, "Intermittent Incident"

.

NO

>> Replace EGR volume control valve. Refer to 

EC-600, "ENGINE CONTROL SYSTEM :

Component Parts Location"

.

Component Inspection (EGR Volume Control Valve)

INFOID:0000000012198487

1.

CHECK EGR VOLUME CONTROL VALVE-1

With CONSULT

1. Turn ignition switch ON and engine stopped.

2. On the CONSULT screen, select “ENGINE” >> “ACTIVE TEST” >> “EGR CONTROL VALVE”.

3. Operate “Up” or “Down”, set “EGR VALVE POSITION” to 0 deg, and check value “V1” of “EGR VALVE

POSITION SEN”.

Does “V1” become 1.2

±0.15 V?

YES

>> GO TO 2.

NO

>> Replace EGR volume control valve. Refer to 

EC-600, "ENGINE CONTROL SYSTEM :

Component Parts Location"

.

2.

CHECK EGR VOLUME CONTROL VALVE-2

With CONSULT

1. Operate “Up” or “Down”, set “EGR VALVE POSITION” to 70 deg, and check value “V2” of “EGR VALVE

POSITION SEN”.

Does “V2” become 4.0

±0.15 V?

YES

>> GO TO 3.

NO

>> Replace EGR volume control valve. Refer to 

EC-600, "ENGINE CONTROL SYSTEM :

Component Parts Location"

.

3.

CHECK EGR VOLUME CONTROL VALVE VISUALLY

1. Turn ignition switch OFF.

2. Check if any foreign objects interferes with EGR volume control valve.
Is the inspection result normal?

EGR volume control valve

ECM

Continuity

Connector

Terminal

Connector

Terminal

F74

5

F23

43

Existed

EGR volume control valve

ECM

Continuity

Connector

Terminal

Connector

Terminal

F74

4

F24

68

Existed

P044A, P044E EGR VOLUME CONTROL VALVE POSITION SENSOR

EC-995

< DTC/CIRCUIT DIAGNOSIS >

[MR EXCEPT FOR NISMO RS MODELS]

C

D

E

F

G

H

I

J

K

L

M

A

EC

N

P

O

YES

>> INSPECTION END

NO

>> Repair or replace the error-detected parts.

EC-996

< DTC/CIRCUIT DIAGNOSIS >

[MR EXCEPT FOR NISMO RS MODELS]

P044B EXHAUST GAS RECIRCULATION SYSTEM

P044B EXHAUST GAS RECIRCULATION SYSTEM

DTC Logic

INFOID:0000000012198488

DTC DETECTION LOGIC

DTC CONFIRMATION PROCEDURE

1.

PRECONDITIONING

If DTC Confirmation Procedure has been previously conducted, always perform the following procedure

before conducting the next test.

1. Turn ignition switch OFF and wait at least 10 seconds.

2. Turn ignition switch ON.

3. Turn ignition switch OFF and wait at least 10 seconds.

TEST CONDITION:

Before performing the following procedure, confirm that battery voltage is 11 V or more at ignition switch ON.

>> GO TO 2.

2.

PERFORM DTC CONFIRMATION PROCEDURE

1. Turn ignition switch ON.

2. Select “DATA MONITOR” mode with CONSULT.

3. Check that “COOLANT TEMP/S” indicates 65

°C (149°F) or more.

4. Check that “INT/A TEMP SE” indicates 5

°C (41°F) or more.

5. Check 1st trip DTC.
Is 1st trip DTC detected?

YES

>> Proceed to 

EC-996, "Diagnosis Procedure"

.

NO

>> INSPECTION END

Diagnosis Procedure

INFOID:0000000012198489

1.

CHECK EGR VOLUME CONTROL VALVE POSITION SENSOR POWER SUPPLY

1. Turn ignition switch OFF.

2. Disconnect EGR volume control valve harness connector.

3. Turn ignition switch ON.

4. Check voltage between EGR volume control valve harness connector and ground.

DTC No.

Trouble diagnosis name

(Trouble diagnosis content)

DTC detecting condition

Possible cause

P044B

EGR SENSOR C
(EGR sensor C circuit range/
performance)

ECM detects the following status continuously 
for 0.5 seconds or more:
A voltage signal transmitted from the EGR vol-
ume control valve position sensor is between 
0.32 V and 1.08 V under the following condi-
tions:
• After the ignition switch is turned OFF and 

the engine is stopped by “Self Shut-OFF”.
This diagnosis works only when the ignition 
switch is turned OFF and the engine is 
stopped by “Self Shut-OFF”.

• Engine coolant temperature: 65

°C (149°F) 

or more

• Intake air temperature: 5

°C (41°F) or more

• EGR volume control valve is stuck
• EGR volume control valve is jammed 

with foreign objects

• Improper specification of EGR vol-

ume control valve position sensor

+

Voltage

(Approx.)

EGR volume control valve

Connector

Terminal

F74

3

Ground

5 V

 

 

 

 

 

 

 

Content   ..  543  544  545  546   ..