SC-8
< SERVICE INFORMATION >
STARTING SYSTEM
STARTING SYSTEM
System Description
INFOID:0000000001328246
Power is supplied at all times
• through 40A fusible link (letter F, located in the fuse and fusible link block)
• to ignition switch terminal 1,
• through 15A fuse (No. 78, located in the IPDM E/R)
• to CPU of IPDM E/R,
• through 10A fuse (No. 71, located in the IPDM E/R)
• to CPU of IPDM E/R.
When the selector lever in the P or N position, power is supplied
• from TCM, and through A/T assembly terminal 9
• to IPDM E/R terminal 53.
Ground is supplied
• to IPDM E/R terminals 38, 50 and 60
• from grounds E21, E50 and E51.
With the ignition switch in the START position, and provided that the IPDM E/R receives a starter relay ON sig-
nal from the CAN lines, the IPDM E/R is energized and power is supplied
• from ignition switch terminal 5
• to IPDM E/R terminal 4 and
• through IPDM E/R terminal 3
• to starter motor terminal 1.
The starter motor plunger closes and provides a closed circuit between the battery and starter motor. The
starter motor is grounded to the engine block. With power and ground supplied, cranking occurs and the
engine starts.