Dacia Solenza (engine E7J). Manual - part 42

 

  Index      Dacia     Dacia Solenza (engine E7J) - service repair manual 2004 year

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  40  41  42  43   ..

 

 

Dacia Solenza (engine E7J). Manual - part 42

 

 

IGNITION AND  INJECTION

17

17 - 74

ET070

CLIMATE CONTROL COMPRESSOR

RECOMMENDATIONS No failure must be present or memorized.

Check the insulation and continuity on the line starting from pin 10 of the injection computer.
Mend if necessary.

If the incident is persisting, consult the climate control diagnostic

Diagnostic – States interpretation

AFTER

Restart the conformity checking from the beginning.

REPARATION

IGNITION AND  INJECTION

17

17 - 75

PR001

 MANIFOLD PRESSURE

RECOMMENDATIONS

No failure must be present or memorized.

Incoherent manifold

Check the insulation, continuity and the absence of the parasite

pressure, contact on

resistance of the connections between:
Pin 15 injection computer      > p

in A pressure transducer

Manifold pressure <

Pin 16 injection computer      > pin B pressure transducer

minimal pressure at

Pin 78 injection computer      > p

in C pressure transducer

idling

 Mend if necessary.

Incoherent

atmospheric

If all checked elements are correct, replace the transducer.

 pressure

(PR016)

Manifold pressure >

 Check :

maximal pressure

- Sealing between manifold and transducer.

at idling

- Valves clearance.
- Canister purging valve operation
- Cylinders compression
- Lack of leaking at inlet manifold (“false air”)
- Exhaust is not clogged.

If all these elements are correct, replace the transducer.

Diagnostic – Parameters interpretation

AFTER

Restart the conformity checking from the beginning.

REPARATION

IGNITION AND  INJECTION

17

17 - 76

PR002

WATER TEMPERATURE

RECOMMENDATIONS

 No failure must be present or memorized.

If the value red is incoherent, check that sensor is correctly following the standard curve “resistance
subject to temperature”.
Replace the sensor if this is presenting deviations (Observation: the presence of the deviations from
normal values of a sensor are often due further  to an electric shock).

Check the insulation, continuity and the absence of the parasite resistance of the connections
between:
   Pin 13 injection computer     > pin B2 water temperature sensor
   Pin 73 injection computer     > pin  B1 water temperature sensor
Mend if necessary.

Diagnostic – Parameters interpretation

AFTER

Restart the conformity checking from the beginning.

REPARATION

IGNITION AND  INJECTION

17

17 - 77

ET003

AIR TEMPERATURE

RECOMMENDATIONS

No failure must be present or memorized.

If the value red is incoherent, check that sensor is correctly following the standard curve
“resistance subject  to  temperature”.
Replace the sensor if this is presenting deviations (Observation: the presence of the deviations
from normal values of a sensor are often due further  to an electric shock).

Check the insulation, continuity and the absence of the parasite resistance of the connections
between:
   Pin 49 injection computer       > pin 1 air temperature sensor
   Pin 77 injection computer       >

 pin  2 air temperature sensor.

Mend if necessary.

Diagnostic – Parameters interpretation

AFTER

Restart the conformity checking from the beginning.

REPARATION

 

 

 

 

 

 

 

Content   ..  40  41  42  43   ..