2. CHECK (P392) DOOR LOCK DRIVER RIGHT DOORS FOR Note: If only one motor is inoperative when the door locks are Turn the ignition off. Disconnect the Cluster C1 connector. Measure the resistance between ground and the (P392) Door Lock Is the resistance below 1000.0 ohms? No >> Go To 3 Yes >> Repair the (P392) Door Lock Driver Right Doors circuit for a short to ground. Perform BODY VERIFICATION TEST - VER 1. 3. CHECK (P393) DOOR LOCK DRIVER LEFT DOORS CIRUIT Measure the resistance between ground and the (P393) Door Lock Is the resistance below 1000.0 ohms? No >> Go To 4 Yes >> Repair the (P393) Door Lock Driver Left Doors circuit for a short to ground. Perform BODY VERIFICATION TEST - VER 1. 4. CHECK THE (P392) DOOR LOCK DRIVER RIGHT DOORS Measure the resistance between the (P392) Door Lock Driver Right Is the resistance below 1.6 ohms? No >> Go To 5 Yes >> Repair the (P392) Door Lock Driver Right Doors circuit for a short to the (G778) Door Unlock Driver Right Doors cir- Perform BODY VERIFICATION TEST - VER 1. HB POWER LOCKS - ELECTRICAL DIAGNOSTICS 8N - 25 B182D-ALL DOOR LOCK OUTPUT CIRCUIT SHORTED TO GROUND — CLUSTER — (CONTINUED) |