Charging batteries

BATTERIES

2-3

Buffer charging

-

With this method, the consumer and the

charger are both connected to the battery.

The charger delivers sufficient current to

ensure that the battery remains virtually fully

charged. The battery will deliver peak

currents to the consumer.

-

Buffer charging is best done at a constant

(stabilised) voltage.

Trickle charging

-

A fully charged battery that is not used for

some time will start to discharge of its own

accord. It may discharge at a rate of 0.1%

to 1% per day. Trickle charging

compensates for such discharges.

-

The charging current for trickle charging

should be around 0.1 A per 100 Ah.

4

 200440

5

BATTERIES

Charging batteries

LF45/55 series

2-4

 200440

4

5

LF45/55 series

Storage of batteries

BATTERIES

3-1

3. STORAGE OF BATTERIES

3.1 GENERAL

Before storing batteries, carry out the following

operations:

1. Remove the battery clamps.

2. Clean the battery terminals and the top of

the batteries.

3. Grease the battery terminals with petroleum

jelly.

4. Check the electrolyte level. The electrolyte

level must be approx. 10 mm above the

plates or up to the level indicator, if there is

one.

If necessary, top up the batteries with

distilled water.

5. Check the charging condition of the

batteries and charge them if necessary. See

the section “Inspection and adjustment”.

3.2 STORAGE UP TO FOUR WEEKS.

If batteries (whether as separate units or fitted in

a vehicle) are not going to be used for an

extended period of time not exceeding four

weeks, the following measures should be taken:

1. Do not connect the battery leads to the

batteries.

2. Check the battery charge level regularly.

See “Inspection and adjustment”.

If the voltage falls below 12.4 volts, or if the

relative density of the electrolyte in one or

more of the cells is less than 1.23 kg/dm

3

,

the battery must be charged.

Note:

The higher the ambient temperature, the more

rapidly the battery discharges.

The lower the relative density of the electrolyte,

the higher the risk of the battery freezing.

 200440

4

5

BATTERIES

Storage of batteries

LF45/55 series

3-2

3.3 STORAGE FOR MORE THAN FOUR WEEKS

If the batteries will not be used for more than

four weeks, the following measures should be

taken:

1. Remove the batteries from the vehicle and

store them in a frost-free, dry, cool and well

ventilated room.

2. Check the charging condition of the

batteries regularly, at least once every four

weeks. See “Inspection and adjustment”.

If the voltage falls below 12.4 volts, or if the

relative density of the electrolyte in one or

more of the cells is less than 1.23 kg/dm

3

,

the battery must be charged.

3. Limit the storage period to a maximum of

three months. The longer the period of

storage, the greater the permanent loss of

capacity.