DAF LF45, LF55 Series. Manual - part 348

 

  Index      DAF     DAF LF45, LF55 Series - service repair manual

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  346  347  348  349   ..

 

 

DAF LF45, LF55 Series. Manual - part 348

 

 

5

LF45/55 series

Safety instructions

BATTERIES

1-1

1. SAFETY INSTRUCTIONS

1.1 BATTERIES

-

Always remove the earth lead before

working on batteries.

-

When connecting battery leads, always

connect the earth lead last.

-

Always handle batteries carefully and hold

them upright.

-

The sulphuric acid in the batteries is an

aggressive and poisonous liquid. While

working on batteries, wear protective

clothing, gloves and safety goggles.

-

In case of contact with cloths, the skin or

the eyes, wash immediately with copious

amounts of water. Consult a doctor in case

of contact with eyes or skin.

-

When topping up batteries, never allow the

fluid level to rise more than 10 mm above

the plates or to go higher than the

level indicator.

-

Never put down tools or other materials that

could accidentally short-circuit the battery

terminals on the batteries or in the vicinity of

batteries. Short-circuited battery terminals

may cause the battery to explode.

-

Secure the batteries well after completing

the work, but not too tightly.

1.2 BATTERY CHARGING

-

During battery charging, an explosive gas

mixture may be released.

-

Only charge batteries in a well ventilated

area.

-

Never smoke or allow naked flames or

sparks in the vicinity of the battery.

-

Allow frozen batteries to thaw before

charging.

-

Switch the charger off before disconnecting

the leads to the battery.

 200440

4

5

BATTERIES

Safety instructions

LF45/55 series

1-2

4

 200440

5

LF45/55 series

Charging batteries

BATTERIES

2-1

2. CHARGING BATTERIES

2.1 GENERAL

-

A battery may only be charged using DC

current. Connect the positive terminal of the

battery to the positive (+) connection of the

charger and the negative terminal of the

battery to the negative (--) connection of the

charger.

The cell sealing plugs may remain on the

battery during charging (except during fast

charging).

During charging, the cell voltage will rise.

This increase in voltage depends on the

charging current applied and the

temperature. During normal charging, the

cell voltage will rise from about 2 volts/cell

to about 2.65 volts/cell. If a charging voltage

of about 2.35 to 2.4 volts/cell (about

14.2 volts in a 12 V battery) is exceeded,

this will start off active gas development.

As a consequence of the rise in voltage

during charging, the charging current will,

as a rule, fall gradually.

Overcharging will reduce the service life of

a battery.

-

If the charging of the battery is continued

after it has been fully charged (even with a

low current), this will lead to corrosion

(corrosive attack) of the grids of the positive

battery plates. This type of wear leads to

premature redundancy of the battery.

Depending on the capacity of the charger,

the normal charging time is between 8 and

15 hours.

If during charging the temperature of the

battery acid rises to more than 55_C, the

charging should be stopped. High

temperatures reduce the service life of the

battery.

-

A battery may be said to be charged if the

charging voltage has not increased for more

than 2 hours and the acid density (relative

density) has reached the nominal value (for

example, 1.28 kg/dm

3

) and does not rise

further.

4

 200440

5

BATTERIES

Charging batteries

LF45/55 series

2-2

-

A charged battery must be used

immediately. If this is not possible, maintain

the battery as described in the section

“Storage of batteries”.

-

A discharged battery must be charged as

soon as possible. If a discharged battery is

not recharged, the battery plates may

become sulphated (i.e. hard), which will

lead to permanent loss of capacity.

2.2 METHODS OF CHARGING

Always disconnect the battery

clamps before charging.

Normal charging

-

Normal charging is done to restore partially

or fully discharged batteries to full capacity.

In most cases, a charging current of

1

/

20

to

1

/

10

of the capacity is selected.

-

It is important to reduce the charging

current during gas development and to

switch the charger off when the battery is

charged.

Fast charging

-

With this charging method, multiples of the

normal charge current (approx. 3 to 5 times)

are used in order to achieve an acceptable

charge condition in the shortest possible

time.

-

Before fast charging, remove the battery

leads in order to prevent damage to the

electronic components.

-

Remove the cell sealing plugs so that the

released gases can easily escape.

-

To prevent overcharging, switch to a lower

charging current on reaching the gas

pressure (2.35 to 2.4 volts/cell).

Note:

Avoid fast charging. Only use this method in

exceptional cases. Fast charging causes

battery overloading, which reduces the

service life of the battery.

4

 200440

 

 

 

 

 

 

 

Content   ..  346  347  348  349   ..