01-242
Display group 57 - Speed control - Idling stabilization Engine running at idle Read measured value
Indicated on display
xxxx xxxx Text ---
1 2 3 4 Display zones Specification Evaluation
No display --- ---
Air conditioning compressor (Compr. ON / Compr. OFF) Compr. ON or Compr. OFF ---
Engine speed (specified idle 700 rpm ---
Engine speed (actual idle speed) 640...720 rpm
Page 01- 188
Notes on display zones 1 and 2: The rpm in display zone 1 (measured revolutions) is the actual engine speed. The rpm in display zone 2 (specified rpm) is theoretical engine speed calculated by the Motronic Engine Control Module (ECM) -J220-. at idle, the Motronic Engine Measured value (data) blocks |