The monitor result might on rare occasions be PASS even if the malfunction indicator lamp (MIL) is illuminated. This indicates the system malfunctioned on a previous driving cycle. This might be caused by 4. MONITOR RESULT INFORMATION If you use a generic scan tool, multiply the test value by the scaling value listed below. A/F Sensor (for Bank 1 Sensor 1) MONITOR ID TEST ID SCALING UNIT DESCRIPTION $01 $93 Multiply by 0.00012 V Rich to Lean response rate deterioration level $01 $94 Multiply by 0.00012 V Lean to Rich response rate deterioration level $01 $95 Multiply by 0.001 Seconds Rich to Lean delay level $01 $96 Multiply by 0.001 Seconds Lean to Rich delay level $01 $91 Multiply by 0.004 mA A/F sensor current A/F Sensor (for Bank 2 Sensor 1) MONITOR ID TEST ID SCALING UNIT DESCRIPTION $05 $93 Multiply by 0.00012 V Rich to Lean response rate deterioration level $05 $94 Multiply by 0.00012 V Lean to Rich response rate deterioration level $05 $95 Multiply by 0.001 Seconds Rich to Lean delay level $05 $96 Multiply by 0.001 Seconds Lean to Rich delay level $05 $91 Multiply by 0.004 mA A/F sensor current HO2 Sensor (for Bank 1 Sensor 2) MONITOR ID TEST ID SCALING UNIT DESCRIPTION $02 $08 Multiply by 0.001 V Maximum sensor voltage $02 $8D Multiply by 0.001 Seconds Duration that sensor voltage drops to 0.2 V during fuel-cut $02 $8F Multiply by 0.0003 g Maximum oxygen storage capacity $02 $90 Multiply by 0.001 No dimension Response rate during fuel cut from rich condition (Normalization) HO2 Sensor (for Bank 2 Sensor 2) MONITOR ID TEST ID SCALING UNIT DESCRIPTION $06 $08 Multiply by V Maximum sensor voltage 1UR-FE ENGINE CONTROL SYSTEM: SFI SYSTEM: CHECKING... |