GD(H6DO)-176 Diagnostic Trouble Code (DTC) Detecting Criteria GENERAL DESCRIPTION 5. DIAGNOSTIC METHOD • Abnormality Judgement If the duration of time while the following conditions are met is longer than the time indicated, judge as NG. Time Needed for Diagnosis:4 ms × 625 time(s) • Normality Judgement Judge as OK and clear the NG if the continuous time while the following conditions are established is more Time Needed for Diagnosis:4 ms × 2 time(s) Judgement Value Malfunction Criteria Threshold Value Terminal voltage level when ECM out- Low level Judgement Value Malfunction Criteria Threshold Value Terminal voltage level when ECM out- High level |