CHANGED BY EFFECTIVE DATE AFFECTED VIN 28 FFH & PTC STAVIC - 2004.09 3B Fan wheel or combustion air fan motor blocked (frozen, • Eliminate blockage • Measure speed of combustion air fan motor: - dismantle combustion air fan - check with 8.2 V + 0.2 V, to do so, unclip the cable 0.75 2 black from chamber 13 of the 14-pin connector and the 2 brown from chamber 14. Apply marking (white paint) to the fan wheel and measure speed with contactless If the measured speed is outside a range of 8,800 rpm to • Check cable harness for this component for damage and through current • Check plug-in connection, replace component if necessary • Fan wheel or combustion air fan motor blocked (contaminated, stiff) • Check cable harness of this component for damage, if neces- sary replace component • Check whether the lead to this component has a short-circuit to GND, if not, check component for ground contact, if neces- • Check cable harness to the external component for damage and through current and replace external component if neces- • Check cable harness to the external component for damage and through current • Check plug-in connection, replace external component if necessary • Check whether lead to this component has short-circuit to +Ub, if not, check component for ground contact, replace Too many start attempts, the controller is locked • Delete the fault memory to release the controller • Check fuel quantity and fuel supply • During start (no flame formed yet), the flame sensor reports temperature value too high for too long • Check exhaust and combustion air • Check flame sensor Remedies Trouble Description Trouble Code 30 31 32 34 47 48 49 50 51 Speed of combustion fan motor out- Burner motor interruption Overload, short-circuit or ground Burner motor output defect Overload, short-circuit or ground Fuel pump interruption Fuel pump output defect Operating block because too many Time exceeded for cold blowing |