P0461 FUEL LEVEL SENSOR EC-739 < COMPONENT DIAGNOSIS > [VQ40DE] C D E F G H I J K L M A EC N P O 13. Confirm whether the voltage changes more than 0.03V during step 7 to 10 and 10 to 12. If NG, go to WITH GST NOTE: Prepare a fuel container and a spare hose. 2. Release fuel pressure from fuel line. Refer to . 3. Remove the fuel feed hose on the fuel level sensor unit. 4. Connect a spare fuel hose where the fuel feed hose was removed. 5. Turn ignition switch ON. 6. Drain fuel by 30 (7-7/8 US gal, 6-5/8 Imp gal) from the fuel tank using proper equipment. 7. Confirm that the fuel gauge indication varies. 8. Fill fuel into the fuel tank for 30 (7-7/8 US gal, 6-5/8 Imp gal). 9. Confirm that the fuel gauge indication varies. 10. If NG, go to Diagnosis Procedure INFOID:0000000005273709 1. CHECK COMBINATION METER FUNCTION . OK or NG OK >> GO TO 2. NG >> Go to MWI-32, "Component Function Check" . 2. CHECK INTERMITTENT INCIDENT GI-46, "Intermittent Incident" . >> INSPECTION END |