DLK-354 < DTC/CIRCUIT DIAGNOSIS > SLIDING DOOR TOUCH SENSOR 3. Check continuity between sliding door control unit RH harness connector and ground. Is the inspection result normal? YES >> GO TO 4. NO >> Repair or replace harness. 4. CHECK SLIDING DOOR TOUCH SENSOR GROUND CIRCUIT 2 1. Connect sliding door control unit RH connector and sliding door touch sensor RH connector. 2. Check voltage between sliding door control unit RH harness connector and ground. Is the inspection result normal? YES >> GO TO 5. NO >> Replace sliding door control unit RH. Refer to DLK-500, "LH : Removal and Installation" . 5. CHECK SLIDING DOOR TOUCH SENSOR DLK-354, "SLIDING DOOR RH : Component Inspection" Is the inspection result normal? YES >> GO TO 6. NO >> Replace sliding door touch sensor RH. 6. CHECK INTERMITTENT INCIDENT GI-42, "Intermittent Incident" >> INSPECTION END SLIDING DOOR RH : Component Inspection INFOID:0000000009649306 1. CHECK SLIDING DOOR TOUCH SENSOR RH 1. Turn ignition switch OFF. 2. Disconnect sliding door touch sensor RH connector. 3. Check resistance between sliding door touch sensor RH terminals. Is the inspection result normal? YES >> INSPECTION END NO >> Replace sliding door touch sensor RH. Sliding door control unit RH Sliding door touch sensor RH Continuity Connector Terminal Connector Terminal B247 23 D173 2 Existed Sliding door control unit RH Ground Continuity Connector Terminal B247 23 Not existed (+) (–) Voltage Sliding door control unit RH Connector Terminal B247 23 Ground 0 V Sliding door touch sensor RH Condition Resistance Terminal 1 2 Sliding door touch sen- Detect obstruction 120 Ω or less Other than above 1 k Ω
± 10% |