TM-112

< DTC/CIRCUIT DIAGNOSIS >

[CVT: RE0F08B]

P0710 TRANSMISSION FLUID TEMPERATURE SENSOR A

P0710 TRANSMISSION FLUID TEMPERATURE SENSOR A

Description

INFOID:0000000009948960

• CVT fluid temperature sensor is installed to control valve.
• CVT fluid temperature sensor detects CVT fluid temperature in oil pan.
• The CVT fluid temperature sensor converts CVT fluid temperature into output voltage and transmits the sig-

nal to TCM.

• The CVT fluid temperature sensor uses a thermistor and its electrical resistance varies as the temperature

varies. The electrical resistance decreases as the temperature increases.

DTC Logic

INFOID:0000000009948961

DTC DETECTION LOGIC

DTC CONFIRMATION PROCEDURE

CAUTION:

Always drive vehicle at a safe speed.
NOTE:
Immediately after performing any “DTC CONFIRMATION PROCEDURE”, always turn ignition switch OFF.
Then wait at least 10 seconds before performing the next test.

1.

CHECK DTC DETECTION (PART 1)

1.

Start the engine.

2.

Maintain the following condition for 5 seconds or more.

3.

Stop the vehicle.

4.

Check the first trip DTC.

Is “P0710” detected?

YES

>> Go to 

TM-113, "Diagnosis Procedure"

.

NO

>> GO TO 2.

2.

CHECK DTC DETECTION (PART 2)

With CONSULT

1.

Turn ignition switch OFF and cool the engine.

2.

Turn ignition switch ON.

CAUTION:

Never start the engine.

3.

Select “Data Monitor” in “TRANSMISSION”.

4.

Select “FLUID TEMP”.

5.

Record CVT fluid temperature.

6.

Start the engine and wait for at least 3 minutes.

DTC

Trouble diagnosis name

DTC is detected if...

Possible cause

P0710

Transmission Fluid Tempera-
ture Sensor A Circuit

• CVT fluid temperature does not rise to 10

°

(50

°

F) after driving for a certain period of 

time with the TCM-received fluid tempera-
ture sensor value between 

40

°

C (

40

°

F) 

and 9

°

C (48.2

°

F).

• CVT fluid temperature sensor value that 

TCM receives is more than 180

°

C (356

°

F)

• TCM-received CVT fluid temperature sen-

sor value while driving is less than 

40

°

C (

40

°

F)

• When compared with value of ECT sensor 

temperature,

- the value of CVT fluid temperature sensor is 

higher by more than 38

°

C (100

°

F).

- the value of CVT fluid temperature sensor is 

lower by more than 27

°

C (81

°

F).

• Harness or connectors

(CVT fluid temperature sensor circuit is 
open or shorted.)

• CVT fluid temperature sensor

Vehicle speed

: 20 km/h (12 MPH) or more

P0710 TRANSMISSION FLUID TEMPERATURE SENSOR A

TM-113

< DTC/CIRCUIT DIAGNOSIS >

[CVT: RE0F08B]

C

E

F

G

H

I

J

K

L

M

A

B

TM

N

O

P

7.

Drive the vehicle for the total minutes specified in the Driving time column below with the following condi-
tions satisfied.

8.

Stop the vehicle.

9.

Check the first trip DTC.

With GST

1.

Turn ignition switch OFF and cool the engine.

2.

Start the engine and wait for at least 3 minutes.

3.

Drive the vehicle and maintain the following conditions for 18 minutes or more.

4.

Stop the vehicle.

5.

Check the first trip DTC.

Is “P0710” detected?

YES

>> Go to 

TM-113, "Diagnosis Procedure"

.

NO

>> GO TO 3.

3.

CHECK CVT FLUID TEMPERATURE SENSOR

1.

Turn ignition switch OFF.

2.

Disconnect CVT unit connector.

3.

Check resistance between CVT unit connector terminals. 

Is the inspection result normal?

YES

>> INSPECTION END

NO

>> Replace the transaxle assembly due to malfunction in the CVT fluid temperature sensor. Refer to

TM-235, "Exploded View"

.

Diagnosis Procedure

INFOID:0000000009948963

1.

CHECK CVT FLUID TEMPERATURE SENSOR CIRCUIT (PART 1)

1.

Turn ignition switch ON.

2.

Check resistance between TCM vehicle side harness connector terminals.

Selector lever

: “D” position

Accelerator pedal position

: 1.0/8 or more

Vehicle speed

: 10 km/h (7 MPH) or more

CVT fluid temperature before engine start

Driving time

40

°

C (

40

°

F) – 

31

°

C (

23.8

°

F)

18 minutes or more

30

°

C (

22

°

F) – 

21

°

C (

5.8

°

F)

16 minutes or more

20

°

C (

4

°

F) – 

11

°

C (

12.2

°

F)

13 minutes or more

10

°

C (14

°

F) – 

1

°

C (30.2

°

F)

10 minutes or more

0

°

C (32

°

F) – 9

°

C (48.2

°

F)

7 minutes or more

10

°

C (50

°

F) or more

(Go to 3.)

Selector lever

: “D” position

Accelerator pedal position

: 1.0/8 or more

Vehicle speed

: 10 km/h (7 MPH) or more

CVT unit

Condition

Resistance

(Approx.)

Connector

Terminal

F24

17

19

When CVT fluid temperature is 20

°

C (68

°

F)

6.83 – 6.29 k

When CVT fluid temperature is 50

°

C (122

°

F)

2.25 – 2.10 k

When CVT fluid temperature is 80

°

C (176

°

F)

0.90 – 0.85 k

TM-114

< DTC/CIRCUIT DIAGNOSIS >

[CVT: RE0F08B]

P0710 TRANSMISSION FLUID TEMPERATURE SENSOR A

Is the inspection result normal?

YES

>> GO TO 2.

NO

>> GO TO 3.

2.

CHECK CVT FLUID TEMPERATURE SENSOR CIRCUIT (PART 2)

1.

Disconnect TCM connector.

2.

Check continuity between TCM vehicle side harness connector terminal and ground.

Is the inspection result normal?

YES

>> Check intermittent incident. Refer to 

GI-40, "Intermittent Incident"

.

NO

>> GO TO 3.

3.

CHECK CVT FLUID TEMPERATURE SENSOR

1.

Turn ignition switch OFF.

2.

Disconnect CVT unit connector.

3.

Check CVT fluid temperature sensor. Refer to 

TM-115, "Component Inspection (CVT Fluid Temperature

Sensor)"

.

Is the inspection result normal?

YES

>> GO TO 4.

NO

>> CVT fluid temperature sensor is malfunctioning. Replace transaxle assembly. Refer to 

TM-235,

"Exploded View"

.

4.

CHECK HARNESS BETWEEN TCM AND CVT UNIT (CVT FLUID TEMPERATURE SENSOR) (PART 1)

1.

Disconnect TCM connector.

2.

Check continuity between TCM vehicle side harness connector terminals and CVT unit vehicle side har-
ness connector terminals.

Is the inspection result normal?

YES

>> GO TO 5.

NO

>> Repair or replace damaged parts.

5.

CHECK HARNESS BETWEEN TCM AND CVT UNIT (CVT FLUID TEMPERATURE SENSOR) (PART 2)

Check continuity between TCM vehicle side harness connector terminals and ground.

Is the inspection result normal?

YES

>> Check intermittent incident. Refer to 

GI-40, "Intermittent Incident"

.

TCM connector

Condition

Resistance (Approx.)

Connector

Terminal

E19

47

 42

CVT fluid temperature: 20

°

C (68

°

F)

6.83 – 6.29 k

CVT fluid temperature: 50

°

C (122

°

F)

2.25 – 2.10 k

CVT fluid temperature: 80

°

C (176

°

F)

0.90 – 0.85 k

TCM vehicle side harness connector

Ground

Continuity

Connector

Terminal

E19

47

Not existed

TCM vehicle side harness connector

CVT unit vehicle side harness connector

Continuity

Connector

Terminal

Connector

Terminal

E19

42

F24

19

Existed

47

17

TCM vehicle side harness connector

Ground

Continuity

Connector

Terminal

E19

42

Not existed

47

P0710 TRANSMISSION FLUID TEMPERATURE SENSOR A

TM-115

< DTC/CIRCUIT DIAGNOSIS >

[CVT: RE0F08B]

C

E

F

G

H

I

J

K

L

M

A

B

TM

N

O

P

NO

>> Repair or replace damaged parts.

Component Inspection (CVT Fluid Temperature Sensor)

INFOID:0000000009948964

1.

CHECK CVT FLUID TEMPERATURE SENSOR (PART 1)

Check resistance between CVT unit harness connector terminals.

Is the inspection result normal?

YES

>> GO TO 2.

NO

>> CVT fluid temperature sensor is malfunctioning. Replace transaxle assembly. Refer to 

TM-235,

"Exploded View"

.

2.

CHECK CVT FLUID TEMPERATURE SENSOR (PART 2)

Check continuity between CVT unit vehicle side harness connector terminal and ground.

Is the inspection result normal?

YES

>> INSPECTION END

NO

>> CVT fluid temperature sensor is malfunctioning. Replace transaxle assembly. Refer to 

TM-235,

"Exploded View"

.

CVT unit harness connector

Condition

Resistance (Approx.)

Connector

Terminal

F24

17

 19

CVT fluid temperature: 20

°

C (68

°

F)

6.83 – 6.29 k

CVT fluid temperature: 50

°

C (122

°

F)

2.25 – 2.10 k

CVT fluid temperature: 80

°

C (176

°

F)

0.90 – 0.85 k

CVT unit harness connector

Ground

Continuity

Connector

Terminal

F24

17

Not existed

 

 

 

 

 

 

 

Content   ..  962  963  964  965   ..