HA-34 < REMOVAL AND INSTALLATION > HEATING AND COOLING UNIT ASSEMBLY 2. Disconnect low-pressure flexible hose from expansion valve. Refer to BLE HOSE : Removal and Installation" 3. Disconnect high-pressure pipe from expansion valve. Refer to . 4. Remove bolts and expansion valve. CAUTION: Cap or wrap the joint of the evaporator and expansion valve with suitable material such as vinyl tape to avoid the entry of air. INSTALLATION Installation is in the reverse order of removal. CAUTION: • Do not reuse O-rings. • Apply compressor oil to new O-rings of the low-pressure flexible hose and high-pressure pipe for installation. • After charging refrigerant, check for leaks. Refer to |