Nissan Rogue. Manual - part 769

 

  Index      Nissan     Nissan Rogue (2015 year) - Service and Repair Manual

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  767  768  769  770   ..

 

 

Nissan Rogue. Manual - part 769

 

 

HAC-98

< SYMPTOM DIAGNOSIS >

[AUTOMATIC AIR CONDITIONING]

INSUFFICIENT COOLING

INSUFFICIENT COOLING

Description

INFOID:0000000011276642

Symptom

• Insufficient cooling

• No cool air comes out. (Air flow volume is normal.)

Diagnosis Procedure

INFOID:0000000011276643

NOTE:

Perform self-diagnosis with CONSULT before performing symptom diagnosis. If any DTC is detected, perform

the corresponding diagnosis.

1.

CHECK MAGNET CLUTCH OPERATION

1. Turn ignition switch ON.

2. Operate fan switch.

3. Press A/C switch.

4. Check that A/C indicator turns ON. Check visually and by sound that A/C compressor operates.

5. Press A/C switch again.

6. Check that A/C indicator turns OFF. Check that A/C compressor stops.
Is the inspection result normal?

YES

>> GO TO 2.

NO

>> Perform diagnosis of “COMPRESSOR DOES NOT OPERATE” in “SYMPTOM DIAGNOSIS”.

Refer to 

HAC-100, "Diagnosis Procedure"

.

2.

CHECK DRIVE BELT

Check tension of drive belt. Refer to 

EM-15, "Checking"

.

Is the inspection result normal?

YES

>> GO TO 3.

NO

>> Adjust or replace drive belt depending on the inspection results.

3.

CHECK REFRIGERANT CYCLE

Connect recovery/recycling recharging equipment to the vehicle and perform pressure inspection with gauge.

Refer to 

HA-17, "Symptom Table"

.

Is the inspection result normal?

YES

>> GO TO 4.

NO

>> Repair or replace parts depending on the inspection results.

4.

CHECK AIR LEAKAGE FROM EACH DUCT

Check duct and nozzle, etc. of the front air conditioning system for leakage.
Is the inspection result normal?

YES

>> GO TO 5.

NO

>> Repair or replace parts depending on the inspection results.

5.

CHECK SETTING OF TEMPERATURE SETTING TRIMMER (FRONT)

1. Check setting value of temperature setting trimmer (front). Refer to 

HAC-50, "Temperature Setting Trim-

mer"

2. Check that temperature setting trimmer (front) is set to “+ direction”. 

NOTE:

The control temperature can be set with the setting of the temperature setting trimmer (front).

3. Set difference between set temperature and control temperature to “0”.
Is inspection result normal?

YES

>> Inspection End.

NO

>> Replace A/C auto amp. Refer to 

HAC-103, "Removal and Installation"

.

INSUFFICIENT HEATING

HAC-99

< SYMPTOM DIAGNOSIS >

[AUTOMATIC AIR CONDITIONING]

C

D

E

F

G

H

J

K

L

M

A

B

HAC

N

O

P

INSUFFICIENT HEATING

Description

INFOID:0000000011276644

Symptom

• Insufficient heating

• No warm air comes out. (Air flow volume is normal.)

Diagnosis Procedure

INFOID:0000000011276645

NOTE:

Perform self-diagnosis with CONSULT before performing symptom diagnosis. If DTC is detected, perform the

corresponding diagnosis.

1.

CHECK COOLING SYSTEM

1. Check engine coolant level and check leakage. Refer to 

CO-8, "Inspection"

.

2. Check reservoir tank cap. Refer to 

CO-12, "RADIATOR CAP : Inspection"

.

3. Check water flow sounds of the engine coolant. Refer to 

CO-8, "Inspection"

.

Is the inspection result normal?

YES

>> GO TO 2.

NO

>> Refill engine coolant and repair or replace parts depending on the inspection results.

2.

CHECK HEATER HOSE

Check installation of heater hose visually or by touching.
Is the inspection result normal?

YES

>> GO TO 3.

NO

>> Repair or replace parts depending on the inspection results.

3.

CHECK HEATER CORE

1. Check temperature of inlet hose and outlet hose of front heater core.

2. Check that inlet side of heater core is hot and the outlet side is slightly lower than/almost equal to the inlet

side.

CAUTION:

Always perform the temperature inspection in a short period of time because the engine coolant

temperature is very hot.

Is the inspection result normal?

YES

>> GO TO 4.

NO

>> Replace heater core. Refer to 

HA-43, "HEATER CORE : Removal and Installation"

.

4.

CHECK AIR LEAKAGE FROM EACH DUCT

Check duct and nozzle, etc. of front air conditioning system for air leakage.
Is the inspection result normal?

YES

>> GO TO 5.

NO

>> Repair or replace parts depending on the inspection results.

5.

CHECK SETTING OF TEMPERATURE SETTING TRIMMER (FRONT)

1. Check setting value of temperature setting trimmer (front). Refer to 

HAC-50, "Temperature Setting Trim-

mer"

2. Check that temperature setting trimmer (front) is set to “

− direction”. 

NOTE:

The control temperature can be set by the temperature setting trimmer (front).

3. Set difference between the set temperature and control temperature to “0”.
Are the symptoms solved?

YES

>> Inspection End.

NO

>> Replace A/C auto amp. Refer to 

HAC-103, "Removal and Installation"

.

HAC-100

< SYMPTOM DIAGNOSIS >

[AUTOMATIC AIR CONDITIONING]

COMPRESSOR DOES NOT OPERATE

COMPRESSOR DOES NOT OPERATE

Description

INFOID:0000000011276646

Symptom: Compressor does not operate.

Diagnosis Procedure

INFOID:0000000011276647

NOTE:

• Perform self-diagnoses with CONSULT before performing symptom diagnosis. If DTC is detected, perform

the corresponding diagnosis.

• Check that refrigerant system is properly charged. If refrigerant amount is below the proper amount, perform

inspection of refrigerant leakage.

1.

CHECK MAGNET CLUTCH OPERATION

Check magnet clutch. Refer to 

HAC-91, "Component Function Check"

Does it operate normally?

YES

>> GO TO 2.

NO

>> Repair or replace malfunctioning parts.

2.

CHECK REFRIGERANT PRESSURE SENSOR

Check refrigerant pressure sensor. Refer to 

EC-485, "Component Function Check"

.

Is the inspection result normal?

YES

>> GO TO 3.

NO

>> Repair or replace malfunctioning parts.

3.

CHECK A/C AUTO AMP. OUTPUT SIGNAL

With CONSULT

Check “COMP REQ SIG” and “FAN REQ SIG” in “Data Monitor” of “HVAC”.

Is the inspection result normal?

YES

>> GO TO 4.

NO

>> Replace A/C auto amp. Refer to 

HAC-103, "Removal and Installation"

.

4.

CHECK ECM INPUT SIGNAL

With CONSULT

Check “AIR COND SIG” and “HEATER FAN SW” in “Data Monitor” of “ECM”.

Is the inspection result normal?

YES

>> GO TO 5.

NO

>> Check CAN communication system. Refer to 

LAN-17, "Trouble Diagnosis Flow Chart"

.

5.

CHECK IPDM E/R INPUT SIGNAL

With CONSULT

1. Start engine.

Monitor item

Condition

Status

COMP REQ SIG

A/C switch

ON

On

OFF

Off

FAN REQ SIG

Blower motor

ON

On

OFF

Off

Monitor item

Condition

Status

AIR COND SIG

A/C switch

ON

On

OFF

Off

HEATER FAN SW

Blower motor

ON

On

OFF

Off

COMPRESSOR DOES NOT OPERATE

HAC-101

< SYMPTOM DIAGNOSIS >

[AUTOMATIC AIR CONDITIONING]

C

D

E

F

G

H

J

K

L

M

A

B

HAC

N

O

P

2. Check “AC COMP REQ” in “Data Monitor” of “IPDM E/R”.

Is the inspection result normal?

YES

>> Inspection End.

NO

>> Check CAN communication system. Refer to 

LAN-17, "Trouble Diagnosis Flow Chart"

.

Monitor item

Condition

Status

AC COMP REQ

A/C switch

ON

On

OFF

Off

 

 

 

 

 

 

 

Content   ..  767  768  769  770   ..