EC-332 < DTC/CIRCUIT DIAGNOSIS > [QR25DE] P0451 EVAP CONTROL SYSTEM PRESSURE SENSOR 1. Turn ignition switch OFF. 2. Disconnect ECM harness connector. 3. Check the continuity between EVAP control system pressure sensor harness connector and ECM har- ness connector. 4. Also check harness for short to ground and to power. YES >> Perform the trouble diagnosis for power supply circuit. NO >> Repair or replace error-detected parts 4. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR GROUND CIRCUIT 1. Turn ignition switch OFF. 2. Disconnect ECM harness connector. 3. Check the continuity between EVAP control system pressure sensor harness connector and ECM har- ness connector. 4. Also check harness for short to power. YES >> GO TO 5. NO >> Repair or replace error-detected parts. 5. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR SIGNAL CIRCUIT 1. Check the continuity between EVAP control system pressure sensor harness connector and ECM har- ness connector. 2. Also check harness for short to ground and to power. YES >> GO TO 6. NO >> Repair or replace error-detected parts. 6. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR Check the EVAP control system pressure sensor. Refer to EC-333, "Component Inspection" Is the inspection result normal? YES >> GO TO 7. NO >> Replace EVAP control system pressure sensor. Refer to FL-22, "Removal and Installation" . 7. CHECK INTERMITTENT INCIDENT GI-44, "Intermittent Incident" + − Continuity EVAP control system pres- sure sensor ECM Connector Terminal Connector Terminal B111 3 E16 113 Existed + − Continuity EVAP control system pres- sure sensor ECM Connector Terminal Connector Terminal B111 1 E16 124 Existed + − Continuity EVAP control system pres- sure sensor ECM Connector Terminal Connector Terminal B111 2 E16 114 Existed |