EXL-28 < FUNCTION DIAGNOSIS > DIAGNOSIS SYSTEM (BCM) 1: With daytime running light system. FLASHER INFOID:0000000004501354 WORK SUPPORT * : Initial setting DATA MONITOR ACTIVE TEST COMB SW CORNERING LAMP 2 RH — LH OFF ILL DIM SIGNAL 2 ON — OFF RR FOG LAMP 2 ON — OFF Test item Operation Description Service item Setting item Setting HAZARD ANSWER LOCK ONLY* Activated when locking. Sets the hazard warning lamp answer back activation UNLK ONLY Activated when unlock- LOCK/UNLK Activated when locking/ OFF Not activated Monitor item [Unit] Description TURN SIGNAL R Each switch condition that BCM judges from the combination switch reading function TURN SIGNAL L HAZARD SW The switch status input from the hazard warning switch RKE LOCK The lock signal status received from the keyless receiver RKE UNLOCK The unock signal status received from the keyless receiver RKE PANIC The panic alarm signal status received from the keyless receiver Test item Operation Description FLASHER RH Blinks right turn signal lamp. LH Blinks left turn signal lamp. OFF Turns turn signal lamps (right and left) OFF. |