POWER SUPPLY AND GROUND CIRCUIT BR-473 < DTC/CIRCUIT DIAGNOSIS > C D E G H I J K L M A B BR N O P Is the inspection result normal? YES >> GO TO 9. NO >> Repair or replace error-detected parts. 9. CHECK TERMINAL • Check for failures in the pin terminals and connections of the electrically-driven intelligent brake unit harness connector. • Check that there is no malfunction in pin terminal and connection of IPDM E/R harness connector. • Check for failures of pin terminals and connections in brake power supply backup unit harness connector. YES >> INSPECTION END NO >> Repair or replace error-detected parts. Brake power supply backup unit — Continuity Connector Terminal B15 2 Ground Existed |