DTC P0447 EVAP CANISTER VENT CONTROL VALVE EC-335 [KA24DE] C D E F G H I J K L M A EC 3. CHECK POWER SUPPLY 1. Turn ignition switch OFF. 2. Disconnect EVAP canister vent control valve harness connector. 3. Turn ignition switch ON. 4. Check voltage between EVAP canister vent control valve termi- OK or NG OK >> GO TO 5. NG >> GO TO 4. 4. DETECT MALFUNCTIONING PART Check the following. ● Harness connectors E43, M65 ● Harness connectors M67, C1 ● Fuse block (J/B) connector E49 ● 10A fuse ● Harness for open or short between EVAP canister vent control valve and fuse >> Repair harness or connectors. 5. CHECK OUTPUT SIGNAL CIRCUIT 1. Turn ignition switch OFF. 2. Disconnect ECM harness connector. 3. Check harness continuity between ECM terminal 108 and terminal 2. 4. Also check harness for short to ground and short to power. OK or NG OK >> GO TO 7. NG >> GO TO 6. SEF143S Voltage : Battery voltage SEF240W Continuity should exist. |