EC-378 [QG (WITH EURO-OBD)] DTC P0605 ECM PROCEDURE FOR MALFUNCTION B With CONSULT-II 1. Turn ignition switch “ON” and wait at least 1 second. 2. Select “DATA MONITOR” mode with CONSULT-II. 3. Turn ignition switch “OFF”, wait at least 10 seconds, and then 4. If 1st trip DTC is detected, go to EC-378, "Diagnostic Procedure" . With GST Follow the procedure “With CONSULT-II” above. PROCEDURE FOR MALFUNCTION C With CONSULT-II 1. Turn ignition switch “ON” and wait at least 1 second. 2. Select “DATA MONITOR” mode with CONSULT-II. 3. Turn ignition switch “OFF”, wait at least 10 seconds, and then 4. Repeat step 3 for 32 times. 5. If 1st trip DTC is detected, go to EC-378, "Diagnostic Procedure" . With GST Follow the procedure “With CONSULT-II” above. Diagnostic Procedure EBS00QOJ 1. INSPECTION START With CONSULT-II 1. Turn ignition switch “ON”. 2. Select “SELF DIAG RESULTS” mode with CONSULT-II. 3. Touch “ERASE”. 4. Perform “DTC Confirmation Procedure”. . 5. Is the 1st trip DTC P0605 displayed again? With GST 1. Turn ignition switch “ON”. 2. Select MODE 4 with GST. 3. Touch “ERASE”. 4. Perform “DTC Confirmation Procedure”. . 5. Is the 1st trip DTC P0605 displayed again? Yes or No Yes >> GO TO 2. No >> INSPECTION END SEF058Y SEF058Y |