содержание .. 223 224 225 226 ..
MWI THE METER CONTROL SWITCH IS INOPERATIVE MWI-59 < SYMPTOM DIAGNOSIS > C D E F G H I J K L M B A O P SYMPTOM DIAGNOSIS THE METER CONTROL SWITCH IS INOPERATIVE Description INFOID:0000000009189357 If any of the following malfunctions are found for the meter control switch operation • All switches are inoperative Diagnosis Procedure INFOID:0000000009189358 1. CHECK METER CONTROL SWITCH SIGNAL CIRCUIT Perform the meter control switch signal circuit inspection. Refer to . Is the inspection result normal? YES >> GO TO 2. NO >> Repair the harnesses or connectors. 2. CHECK METER CONTROL SWITCH Perform the unit inspection of meter control switch. Refer to MWI-44, "Component Inspection" . Is the inspection result normal? YES >> Replace the combination meter. NO >> Replace the meter control switch. |